The connection leads from the operating pa-
nel to the discharge control unit is to be laid
and secured in the same way as the existing
leads to the operating panel. They must not
come in contact with the intermediate wall or
the heating element connections.
2.2.2 Circuit diagram designations
X1
Mains connection terminal
X2
Connection terminal
Discharge control unit
A2
Electronic discharge control
B2
Room temperature sensor - discharge
R2
Adjuster - discharge
S2
ON/OFF switch, discharge control unit
X25 Internal connection strip A1-A2
2.2.3 Night time heating reduction
- connection of an external time-
clock
After installation, a switch or timeclock should
be wired to terminals L and TA on terminal
block X2. A temperature reduction of appro-
ximately 4 K can then be achieved.
The wiring for this modification must be pro-
vided by the installer, they are not included in
the kit.

2.3 Function test

Set the ON/OFF switch to the position " " .
Now rotate the temperature selector button
B2
X20
X17
X13
+ -
X3
DC
Aufladesteuerung
Kleinspannungs-System
10
until the blower of the storage heater swit-
ches on. If the blower does not switch on, the
operating and fault displays on the charge and
discharge control units are to be observed.
2.3.1 Operating and fault display on
the electronic charging regulator
LED lights "green" ⇒ No fault
The charge control unit is working perfectly.
LED lights "red" ⇒ Fault
a) The selector button for charging (R1)
and/or the core sensor (B1) is defective
or not connected.
b) The plug bridge for reducing the degree
of charge at the discharge control unit is
missing.
No charging is taking place.
LED lights "orange" ⇒ Fault at the dischatge
control unit
a) Discharge control unit is defective.
b) Potentiometer for setting the discharge is
defective and/or not connected.
The room temperature will be regulated to
about 22 °C.
c) Room temperature sensor defective and/
or not connected.
No discharge is taking place.

2.4 Handover

These Operating and Installation Instructions
belong to the unit and are to be kept in a safe
A4
R1
R2
L
S2
X21
X22
X23
A2
X25
X16
V4
X14 - X15
X12
X11
A1
R1
B1
TA
N
N
N
N
N
LE` LH
LH`
LE
1
1
5
N4
K1
M3
M2
M1
F2
N5
4
N
3
1
2
X2
L-
A1
A2
L
N
L
SH
Z1
Z2
AC
Aufladesteuerung
230 V-System
1/N/PE
230V
place by the owner. In the event of change of
ownership, they are to be handed over to the
new owner. In the event of any maintenance
or repair work being necessary, the qualified
installer is to be provided with the Operating
and Installation Instructions in order to consult
them.
3. Environment and re-
cycling
Please help us to protect the environment by
disposing of the packaging in accordance with
the national regulations for waste processing.
4. Garantie
For guarantee please refer to the respective
terms and conditions of supply for your coun-
try.
The installation, electrical connection
and fi rst operation of this appliance
should be carried out by a qualifi ed installer.
The company does not accept liability
for failure of any goods supplied which
are not installed in accordance with the
manufacturer's instructions.