  • DEUTSCH, seite 42
• Coupling size of brazed pipe
Connected section
External size
K
External size
Standard outer dia. of
connected copper pipe
Standard outer dia. (Allowable difference)
6.35
9.52
12.70
12.70 (±0.03)
15.88
15.88 (±0.03)
19.05
19.05 (±0.03)
22.22
22.22 (±0.03)
28.58
28.58 (±0.04)
34.92
34.90 (±0.04)
38.10
38.10 (±0.05)
41.28
41.28 (±0.05)
Selection of pipe materials and size
• Selection of pipe material
Material: Phosphorus deoxidation seam-less pipe
• Capacity code of indoor and outdoor units
• For the indoor unit, the capacity code is decided at each capacity rank.
• The capacity codes of the outdoor units are decided at each capacity rank. The maximum No. of connectable
indoor unit and the total value of capacity codes of the indoor units are also decided.
Compared with the capacity code of the outdoor unit, the total value of capacity codes of the connectable indoor
units differs based on the height difference between the indoor units.
• When height difference between the indoor units is below 15m: Up to 135% of capacity code of the outdoor unit
• When height difference between the indoor units is over 15m: Up to 105% of capacity code of the outdoor unit
Table 1
Capacity code
Indoor unit
Equivalent Equivalent
capacity rank
to HP
to capacity
007 type
0.8
2.2
009 type
1
2.8
012 type
1.25
3.6
015 type
1.7
4.5
018 type
2
5.6
024 type
2.5
7.1
027 type
3
8
030 type
3.2
9
036 type
4
11.2
048 type
5
14
056 type
6
16
072 type
8
22.4
096 type
10
28
* For combination of the outdoor units, refer to "Combination of outdoor units".
All manuals and user guides at all-guides.com
Internal size
G
Connected section
Internal siz
C
F
+0.04
6.35 (±0.03)
6.45 (
–0.02
+0.04
9.52 (±0.03)
9.62 (
–0.02
+0.04
12.81 (
–0.02
+0.04
16.00 (
–0.02
+0.03
19.19 (
–0.03
+0.03
22.36 (
–0.03
+0.06
28.75 (
–0.02
+0.04
35.11 (
–0.04
+0.08
38.31 (
–0.02
+0.08
41.50 (
–0.02
Table 2
Capacity code
Outdoor unit
Equivalent Equivalent
model name
to HP
MMY-MAP0501
5
MMY-MAP0601
6
MMY-MAP0801
8
MMY-MAP1001
10
MMY-MAP1201
12
MMY-AP1401
14
MMY-AP1601
16
MMY-AP1801
18
MMY-AP2001
20
MMY-AP2201
22
MMY-AP2211
MMY-AP2401
24
MMY-AP2411
MMY-AP2601
26
Min. depth
of insertion
K
G
)
7
6
)
8
7
)
9
8
)
9
8
)
11
10
)
11
10
)
13
12
)
14
13
)
15
14
)
15
14
No. of
Outdoor unit
indoor
model name
units
to capacity
14
8
MMY-AP2801
16
10
MMY-AP3001
22.4
13
MMY-AP3201
28
16
MMY-AP3211
33.5
20
MMY-AP3401
38.4
23
MMY-AP3411
45
27
MMY-AP3601
50.4
30
MMY-AP3611
56
33
MMY-AP3801
MMY-AP4001
61.5
37
MMY-AP4201
MMY-AP4401
68
40
MMY-AP4601
73
43
MMY-AP4801
12
(Unit: mm)
Min. thickness
of coupling
Oval value
0.06 or less
0.50
0.08 or less
0.60
0.10 or less
0.70
0.13 or less
0.80
0.15 or less
0.80
0.16 or less
0.82
0.20 or less
1.00
0.25 or less
1.20
0.27 or less
1.26
0.28 or less
1.35
Capacity code
No. of
indoor
Equivalent Equivalent
units
to HP
to capacity
28
78.5
30
84
32
90
34
96
36
101
38
106.5
40
112
42
118
44
123.5
46
130
48
135
47
48
48
48
48
48
48
48
48
48