Proline Promass E 200 FOUNDATION Fieldbus
Rela-
Name
tive
Index
40
TRDSUP_SU_RefDensity_1
41
TRDSUP_SU_Temperature_1
42
TRDSUP_SU_Pressure_1
TRDSUP_View1
TRDSUP_StRev
TRDSUP_BlockErr
TRDSUP_TransducerType
TRDSUP_XdError
TRDSUP_BlockErrDesc_1
STD_LockingState
TRDSUP_View2
TRDSUP_StRev
TRDSUP_TransducerType
STD_UserLevel
CFM_FluidSelection
CFM_GasType
CFM_RefSoundVelocity
CFM_TempCoeffSVel
CFM_PressureMode
CFM_FixPressure
FLOW_RefDensityForcing
FLOW_ForcedRefDensity
FLOW_LinearExpansionCoeff
FLOW_SquareExpansionCoeff
FLOW_ReferenceTemperature
FLOW_FlowMonitoringSelector
FLOW_LowFlowLimit
FLOW_LowFlowHysteresis
FLOW_PressureShockSuppression
FLOW_DensityMonitoringSelector
FLOW_MinDensityValue
FLOW_MaxDensityValue
FLOW_DensityMonitoringDelay
SU_MassFlow
SU_VolumeFlow
SU_CorrVolumeFlow
Endress+Hauser
Label
Data type
Reference density unit
ENUM16
Temperature unit
ENUM16
Pressure unit
ENUM16
View -1-
VIEW1
Static Revision
UINT16
Block Error
BIT_ENUM16
Transducer Type
ENUM16
Transducer Error
ENUM8
Block error description
BIT_ENUM32
Locking status
BIT_ENUM16
View -2-
VIEW2
Static Revision
UINT16
Transducer Type
ENUM16
Access status tooling
ENUM16
Select medium
ENUM16
Select gas type
ENUM16
Reference sound velocity
FLOAT
Temperature coefficient
FLOAT
sound velocity
Pressure compensation
ENUM16
Pressure value
FLOAT
Corrected volume flow
ENUM16
calculation
Fixed reference density
FLOAT
Linear expansion
FLOAT
coefficient
Square expansion
FLOAT
coefficient
Reference temperature
FLOAT
Assign process variable
ENUM16
On value low flow cutoff
FLOAT
Off value low flow cutoff
FLOAT
Pressure shock
FLOAT
suppression
Assign process variable
ENUM16
Low value partial filled
FLOAT
pipe detection
High value partial filled
FLOAT
pipe detection
Response time part.
FLOAT
filled pipe detect.
Mass flow unit
ENUM16
Volume flow unit
ENUM16
Corrected volume flow
ENUM16
unit
Storage
Size
MODE_BLK Writa-
Class
(Bytes)
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Dynamic
17
Static
2
Dynamic
2
Static
2
Dynamic
1
Dynamic
4
Dynamic
2
Static
84
Static
2
Static
2
Static
2
Static
2
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO