Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Proline Promass E 200 FOUNDATION Fieldbus Betriebsanleitung Seite 145

Coriolis-durchflussmessgerät;
Vorschau ausblenden Andere Handbücher für Proline Promass E 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Proline Promass E 200 FOUNDATION Fieldbus
Rela-
Name
tive
Index
45
TRDASUP_PFS_StateValueSelector_1
46
TRDASUP_PFS_StateSwitchOnDelay_1
47
TRDASUP_PFS_StateSwitchOffDelay_1
48
TRDASUP_PFS_StateFailsafeMode_1
49
TRDASUP_PFS_StateOutValue_1
50
TRDASUP_PFS_OutSignalInvert_1
51
TRDASUP_STD_SWOptionActiveOverview_1
52
TRDASUP_SU_MassFlow_1
53
TRDASUP_SU_Mass_1
54
TRDASUP_SU_VolumeFlow_1
55
TRDASUP_SU_Volume_1
56
TRDASUP_SU_CorrVolume_1
57
TRDASUP_SU_CorrVolumeFlow_1
58
TRDASUP_SU_Density_1
59
TRDASUP_SU_RefDensity_1
60
TRDASUP_SU_Temperature_1
61
TRDASUP_TIC_Channel_1
62
TRDASUP_TIC_TotUnit_1
63
TRDASUP_TIC_Channel_2
64
TRDASUP_TIC_TotUnit_2
65
TRDASUP_TIC_Channel_3
66
TRDASUP_TIC_TotUnit_3
67
TRDASUP_SU_Pressure_1
68
TRDASUP_CFM_MeasCarrTubeTemp_1
69
TRDASUP_SU_Length_1
TRDASUP_View1
TRDASUP_StRev
TRDASUP_BlockErr
TRDASUP_TransducerType
TRDASUP_XdError
TRDASUP_BlockErrDesc_1
STD_LockingState
PFS_PulseOutValue
PFS_FrequencyOutValue
TRDASUP_View2
TRDASUP_StRev
TRDASUP_TransducerType
SU_MassFlow
SU_Mass
SU_VolumeFlow
Endress+Hauser
Label
Data type
Assign status
ENUM16
Switch-on delay
FLOAT
Switch-off delay
FLOAT
Failure mode
ENUM16
Switch status
ENUM16
Invert output signal
ENUM16
Software option
BIT_ENUM32
overview
Mass flow unit
ENUM16
Mass unit
ENUM16
Volume flow unit
ENUM16
Volume unit
ENUM16
Corrected volume unit
ENUM16
Corrected volume flow
ENUM16
unit
Density unit
ENUM16
Reference density unit
ENUM16
Temperature unit
ENUM16
Assign process variable
ENUM16
Unit totalizer
ENUM16
Assign process variable
ENUM16
Unit totalizer
ENUM16
Assign process variable
ENUM16
Unit totalizer
ENUM16
Pressure unit
ENUM16
Carrier Temperature
ENUM16
Measure supported
Length unit
ENUM16
View -1-
VIEW1
Static Revision
UINT16
Block Error
BIT_ENUM16
Transducer Type
ENUM16
Transducer Error
ENUM8
Block error description BIT_ENUM32
Locking status
BIT_ENUM16
Pulse output
FLOAT
Output frequency
FLOAT
View -2-
VIEW2
Static Revision
UINT16
Transducer Type
ENUM16
Mass flow unit
ENUM16
Mass unit
ENUM16
Volume flow unit
ENUM16
Storage
Size
MODE_BLK Writa-
Class
(Bytes)
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Dynamic
2
Static
2
AUTO
Static
4
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Dynamic
25
Static
2
Dynamic
2
Static
2
Dynamic
1
Dynamic
4
Dynamic
2
Dynamic
4
Dynamic
4
Static
26
Static
2
Static
2
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Anhang
bility
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
145

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis