Herunterladen Inhalt Inhalt Diese Seite drucken

17.1.15 Transducer Block Setup - Endress+Hauser Proline Promass E 200 FOUNDATION Fieldbus Betriebsanleitung

Coriolis-durchflussmessgerät;
Vorschau ausblenden Andere Handbücher für Proline Promass E 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Anhang
Relative
Index
CFM_C4
CFM_C5
Rela-
Name
tive
Index
11
TRDSUP_TransducerTypeVer
12
TRDSUP_XdError
13
TRDSUP_CollectionDirectory
14
TRDSUP_BlockErrDesc_1
15
TRDSUP_STD_UserLevel_1
16
TRDSUP_STD_LockingState_1
17
TRDSUP_CFM_FluidSelection_1
18
TRDSUP_CFM_GasType_1
19
TRDSUP_CFM_RefSoundVelocity_1
20
TRDSUP_CFM_TempCoeffSVel_1
21
TRDSUP_CFM_PressureMode_1
22
TRDSUP_CFM_FixPressure_1
23
TRDSUP_FLOW_RefDensityForcing_1
24
TRDSUP_FLOW_ForcedRefDensity_1
25
TRDSUP_FLOW_LinearExpansionCoeff_1
26
TRDSUP_FLOW_SquareExpansionCoeff_1
27
TRDSUP_FLOW_ReferenceTemperature_1
28
TRDSUP_FLOW_FlowMonitoringSelector_1
29
TRDSUP_FLOW_LowFlowLimit_1
30
TRDSUP_FLOW_LowFlowHysteresis_1
31
TRDSUP_FLOW_PressureShockSuppression_1
32
TRDSUP_FLOW_DensityMonitoringSelector_1
33
TRDSUP_FLOW_MinDensityValue_1
34
TRDSUP_FLOW_MaxDensityValue_1
35
TRDSUP_FLOW_DensityMonitoringDelay_1
36
TRDSUP_SU_MassFlow_1
37
TRDSUP_SU_VolumeFlow_1
38
TRDSUP_SU_CorrVolumeFlow_1
39
TRDSUP_SU_Density_1
200
Name

17.1.15 Transducer Block Setup

Collection Directory
Block error description
Access status tooling
Reference sound velocity
Temperature coefficient
Pressure compensation
Corrected volume flow
Fixed reference density
Square expansion
Reference temperature
Assign process variable
On value low flow cutoff
Off value low flow cutoff
Assign process variable
Low value partial filled
High value partial filled
Response time part.
Corrected volume flow
Proline Promass E 200 FOUNDATION Fieldbus
Label
Data type
C4
STRING
C5
STRING
Label
Data type
UINT16
Transducer Error
ENUM8
UINT32
BIT_ENUM32
ENUM16
Locking status
BIT_ENUM16
Select medium
ENUM16
Select gas type
ENUM16
FLOAT
FLOAT
sound velocity
ENUM16
Pressure value
FLOAT
ENUM16
calculation
FLOAT
Linear expansion
FLOAT
coefficient
FLOAT
coefficient
FLOAT
ENUM16
FLOAT
FLOAT
Pressure shock
FLOAT
suppression
ENUM16
FLOAT
pipe detection
FLOAT
pipe detection
FLOAT
filled pipe detect.
Mass flow unit
ENUM16
Volume flow unit
ENUM16
ENUM16
unit
Density unit
ENUM16
Storage
Size (Bytes) MODE_BLK Writa-
Class
Static
16
AUTO
Static
16
AUTO
Storage
Size
MODE_BLK Writa-
Class
(Bytes)
Static
2
Dynamic
1
Static
4
Dynamic
4
Static
2
Dynamic
2
Static
2
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Endress+Hauser
bility
X
X
bility
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Werbung

Inhaltsverzeichnis
loading