Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Proline Promass E 200 FOUNDATION Fieldbus Betriebsanleitung Seite 168

Coriolis-durchflussmessgerät;
Vorschau ausblenden Andere Handbücher für Proline Promass E 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Anhang
Rela-
tive
Index
77
TRDHBTR1_HBTR_VerificationReferenceTempResult_2
78
TRDHBTR1_HBTR_SensorSymmetryDeviation_2
79
TRDHBTR1_HBTR_ZeroTrackingDeviation_2
80
TRDHBTR1_HBTR_LateralSensorFreqDeviation_2
81
TRDHBTR1_HBTR_ReferenceClockDeviation_2
82
TRDHBTR1_HBTR_ReferenceTempDeviation_2
83
TRDHBTR1_HBTR_MeasCarrTubeTemp_2
84
TRDHBTR1_HBTR_DampingActual_2
85
TRDHBTR1_HBTR_DensityActual_2
86
TRDHBTR1_HBTR_TemperatureActual_2
87
TRDHBTR1_HBTR_MassFlowActual_2
88
TRDHBTR1_HBTR_ElectronicTemperatureActual_2
89
TRDHBTR1_HBTR_CFMVoltages_2
96
TRDHBTR1_STD_LockingState_1
97
TRDHBTR1_SU_VolumeFlow_1
98
TRDHBTR1_SU_MassFlow_1
99
TRDHBTR1_SU_Density_1
100
TRDHBTR1_SU_Temperature_1
101
TRDHBTR1_STD_SWOptionActiveOverview_1
TRDHBTR1_View1
TRDHBTR1_StRev
TRDHBTR1_BlockErr
TRDHBTR1_TransducerType
TRDHBTR1_XdError
TRDHBTR1_BlockErrDesc_1
STD_LockingState
TRDHBTR1_View2
TRDHBTR1_StRev
TRDHBTR1_TransducerType
HBTR_VerificationDateTime
168
Name
Proline Promass E 200 FOUNDATION Fieldbus
Label
Data type
Reference
ENUM16
temperature
Pickup coils
FLOAT
symmetry
deviation
Zero point tracking
FLOAT
deviation
Actual frequency
FLOAT
lateral mode
Reference clock
FLOAT
deviation
Reference
FLOAT
temperature
deviation
Carrier
ENUM16
Temperature
Measure supported
Damping
FLOAT
verification value
Density verification
FLOAT
value
Process
FLOAT
temperature
verification value
Mass flow
FLOAT
verification value
Electronic
FLOAT
temperature
Supply voltage 0
FLOAT
Locking status
BIT_ENUM16
Volume flow unit
ENUM16
Mass flow unit
ENUM16
Density unit
ENUM16
Temperature unit
ENUM16
Software option
BIT_ENUM32
overview
View -1-
VIEW1
Static Revision
UINT16
Block Error
BIT_ENUM16
Transducer Type
ENUM16
Transducer Error
ENUM8
Block error
BIT_ENUM32
description
Locking status
BIT_ENUM16
View -2-
VIEW2
Static Revision
UINT16
Transducer Type
ENUM16
Date/time
STRING
Storage
Size
MODE_BLK Wri-
Class
(Bytes)
Static
2
Static
4
Static
4
Static
4
Static
4
Static
4
Static
2
Static
4
Static
4
Static
4
Static
4
Static
4
Static
4
Dynamic
2
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
4
Dynamic
17
Static
2
Dynamic
2
Static
2
Dynamic
1
Dynamic
4
Dynamic
2
Static
112
Static
2
Static
2
Static
20
Endress+Hauser
tabi-
lity
X
X
X
X

Werbung

Inhaltsverzeichnis
loading