Transducer Block Advanced Setup - Endress+Hauser Proline Promass E 200 FOUNDATION Fieldbus Betriebsanleitung

Coriolis-durchflussmessgerät;
Vorschau ausblenden Andere Handbücher für Proline Promass E 200 FOUNDATION Fieldbus:
Inhaltsverzeichnis

Werbung

Anhang
Rela-
Name
tive
Index
11
TRDASUP_TransducerTypeVer
12
TRDASUP_XdError
13
TRDASUP_CollectionDirectory
14
TRDASUP_BlockErrDesc_1
15
TRDASUP_STD_UserLevel_1
16
TRDASUP_STD_LockingState_1
17
TRDASUP_FLOW_InstallationDirection_1
18
TRDASUP_CFM_ZeroPointAdjustControl_1
19
TRDASUP_CFM_ZeroPointAdjustProgress_1
20
TRDASUP_CFM_ZeroPointAdjustState_1
21
TRDASUP_PFS_OperatingMode_1
22
TRDASUP_PFS_PulseInputSelector_1
23
TRDASUP_PFS_PulseValue_1
24
TRDASUP_PFS_PulseWidth_1
25
TRDASUP_PFS_PulseMeasuringMode_1
26
TRDASUP_PFS_PulseFailsafeMode_1
27
TRDASUP_PFS_PulseOutValue_1
28
TRDASUP_PFS_FrequencyInputSelector_1
29
TRDASUP_PFS_FrequencyMinFrequency_1
30
TRDASUP_PFS_FrequencyMaxFrequency_1
31
TRDASUP_PFS_FrequencyMinValue_1
32
TRDASUP_PFS_FrequencyMaxValue_1
33
TRDASUP_PFS_FrequencyMeasuringMode_1
34
TRDASUP_PFS_FrequencyDamping_1
35
TRDASUP_PFS_OverallSignalDamping_1
36
TRDASUP_PFS_FrequencyFailsafeMode_1
37
TRDASUP_PFS_FrequencyFailsafeValue_1
38
TRDASUP_PFS_FrequencyOutValue_1
39
TRDASUP_PFS_StateMode_1
40
TRDASUP_PFS_MessageSelector_1
41
TRDASUP_PFS_LimitCheckSelector_1
42
TRDASUP_PFS_StateSwitchOnValue_1
43
TRDASUP_PFS_StateSwitchOffValue_1
44
TRDASUP_PFS_DirectionCheckSelector_1
144
17.1.2

Transducer Block Advanced Setup

Label
Transducer Error
Collection Directory
Block error description BIT_ENUM32
Access status tooling
Locking status
Installation direction
Zero point adjustment
control
Adjustment in
progress
Zeropoint adjust state
Operating mode
Assign pulse output
Value per pulse
Pulse width
Measuring mode
Failure mode
Pulse output
Assign frequency
output
Minimum frequency
value
Maximum frequency
value
Measuring value at
minimum frequency
Measuring value at
maximum frequency
Measuring mode
Damping output
Response time
Failure mode
Failure frequency
Output frequency
Switch output function
Assign diagnostic
behavior
Assign limit
Switch-on value
Switch-off value
Assign flow direction
check
Proline Promass E 200 FOUNDATION Fieldbus
Data type
Storage
Class
UINT16
Static
ENUM8
Dynamic
UINT32
Static
Dynamic
ENUM16
Static
BIT_ENUM16
Dynamic
ENUM16
Static
ENUM16
Static
UINT8
Static
ENUM16
Static
ENUM16
Static
ENUM16
Static
FLOAT
Static
FLOAT
Static
ENUM16
Static
ENUM16
Static
FLOAT
Dynamic
ENUM16
Static
FLOAT
Static
FLOAT
Static
FLOAT
Static
FLOAT
Static
ENUM16
Static
FLOAT
Static
FLOAT
Static
ENUM16
Static
FLOAT
Static
FLOAT
Dynamic
ENUM16
Static
ENUM16
Static
ENUM16
Static
FLOAT
Static
FLOAT
Static
ENUM16
Static
Size
MODE_BLK Writa-
(Bytes)
bility
2
1
4
4
2
2
2
AUTO
X
2
AUTO
X
1
2
2
AUTO
X
2
AUTO
X
4
AUTO
X
4
AUTO
X
2
AUTO
X
2
AUTO
X
4
2
AUTO
X
4
AUTO
X
4
AUTO
X
4
AUTO
X
4
AUTO
X
2
AUTO
X
4
AUTO
X
4
2
AUTO
X
4
AUTO
X
4
2
AUTO
X
2
AUTO
X
2
AUTO
X
4
AUTO
X
4
AUTO
X
2
AUTO
X
Endress+Hauser