Herunterladen Diese Seite drucken

Installation Requirements; Correct Installation - HEATSTRIP ELEGANCE Bedienungsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation Requirements

®
The ideal mounting position for the HEATSTRIP
Elegance is on the ceiling directly above the area to be heated. If this is
®
not possible, HEATSTRIP
can be mounted on a wall and angled downwards. In this situation, ensure the mounting height
is in the range of 2.1m to 2.7m and the table is close to the wall.
For mounting heights more than 2.7m, we recommend the use of the optional accessories to reduce the height of the
®
heater to 2.3m—2.5 m. This will increase the effectiveness of your HEATSTRIP
. Refer to the Mounting Accessory section
for more information.
Electrical connections/GPO's should not be located at the back of the heater. They should be located outside the physical
footprint of the units to minimize heat build-up behind the units.
If the heater is to be mounted on an incline (e.g. vaulted ceiling), ensure the electrical connection is located at the lowest
point of the heater.
Incorrect Installation

Correct Installation

The heating surface must never be directed toward the ceiling
10

Werbung

loading