Herunterladen Inhalt Inhalt Diese Seite drucken

AJ 30092 Gebrauchsanleitung Seite 136

Elektrischer arbeitspositionierer
Inhaltsverzeichnis

Werbung

C. WARNINGS
1. Use only on plain and smooth floor.
2. Not to overload, ensure load uniformity. Pay special attention when heavily
loaded.
3. Buzzer beeps to alarm battery low, charge in time or the battery shall be
damaged.
4. Ensure that the input voltage of the charger complies with local power net
voltage.
5. Not to contact chain or other moving parts.
6. Not to carry out long hours of continuous work under heavy duty, lest troubles
from over heated of motor and panel.
7. The working life of the elevator shall be greatly prolonged when working under
0.7 times of the maximum nominal load.
8. Keep the electric control commission box closed before operation.
D. CHECK BEFORE ASSEMBLY
E Series of single pole electric elevator is delivered in box with dis-assembled
parts, and before exit factory, the product is adjusted. Please follow the following
regulations to assemble and inspect the product before putting into use.
1. Ensure the parts received are complete, in good condition and appearance
free from any damage.
2. Connect fast two pieces of front wheel forks (45) by bolts (43) and (46) to the
supports of electric box (3) separately.
3. Connect fast the fixed fork (27) by bolt (28) to safety belt (23), downward/
upward bearing seat (35) separately, without loosening and ensure the safety
belt is totally clamped firmly.
4. Switch (5) power ON without load, (Buzzer may beep, switch off/on again,
beep stops.); operate the hand panel (16),platform (26) climbs smoothly up to
the height maximum, keeps still, and then descends to the lowest position. The
total commission makes no abnormal sound.
5. Repeat the afore mentioned operation under rated load, the platform shall
climb smoothly to the height maximum, stop without slipping, or descend
smoothly to the lowest position and stop then without abnormal sound.
6. The maintenance-free battery, which is provided together with the elevator, has
been initially charged full before exit plant. Provided the interval from exit plant
is relatively long, the battery may be no more full. Hence, for the first time heavy
load climbing when buzzer beeps, it is necessary to charge again before re-use.
E. OPERATION GUIDE
1. Elevator: Operation of Transition, Loading and unloading
1.1. Lock truckles before goods loading and unloading at any height.
1.2. Take care of load uniformity when load and unload; deflected load is always
not appreciated.
1.3. Mention not to loose equilibrium from one-sided unloading lest dangerous
occurrences.
1.4. When it is needed to move the elevator with unfinished unloading, take care
of the uniformity of the goods still needed to be unloaded.
1.5. Lower the platform to the lowest position when the loaded elevator is to
move, so as to ensure safety.
2. Elevator: Operation of Climbing and Descending
2.1. Take care to stop at a right spot and ensure needed operation space when
the elevator is to pile or take off goods for some height.
2.2. Lock the wheels, and switch power on.
2.3. Press on the UP button on the panel, the platform climbs smoothly to the
needed height, and then release the button, the platform keeps still and shall
no slip down. The movable hand control panel is convenient for the operator to
observe and operate on different positions.
2.4. Strictly follow the regulations (1.1, 1.3, 1.4)to operate the elevator when
goods raised up to the needed height for unloading or piling.
2.5. Strictly follow the regulations (1.1, 1.2, 1.5)to operate the elevator when
taking off goods from racket.
2.6. When finishing unloading at some height, press the DOWN button for the
platform descending smoothly; and the Down button can be released at any
height needed while the platform shall stop descending for the elevator to
perform a new job at same spot but different height.
2.7. The elevator is designed to possess the function of overload protection.
Whenever the load surpasses 25% of rated capacity, the platform shall not be
elevated, the elevator shall not be able to carry out the jobs of up-climbing,
down-descending and vehicle transition.
2.8. The elevator is designed to possess the function of low power protection.
Should the battery power is not sufficient for jobs during loaded climbing and
descending, the buzzer beeps for 50 seconds alarm continuously and then cut
off automatically the power circuit with indication light up (operator shall lower
the platform to the lowest position during this period); the elevator is protected
and the operation of climbing or descending is invalid even if the power is still
connected.
3. Battery
3.1. High performance petty maintenance-free sealed acidic-lead storage
battery is selected to power the elevator. It is characterized by low discharge
ability, safe, easy mounting and change-over, and can be used under the
ambient temperature range of -15ºC--50ºC.
3.2. The working life of the battery is greatly depends on the right use. The
working life of the battery shall be greatly shortened when repeatedly used at
the condition of low voltage, and even burn the control element. Considering
of this, the elevator is designed with the function of low voltage protection in
the part of electric control. During the elevator is operating under low voltage
for up-climbing or down-descending, the buzzer shall beep for 50 seconds
continuously and then cut off the power supply. The operator shall charge the
battery in time.
4. Charger
4.1. High performance charger is provided together with the elevator, so that the
battery can be charges at any handy power terminal. Be sure the voltage of local
power net is as needed by the inlet voltage of the charger.
4.2. When charging with switch off elevator power, connect charger source pin
and power terminal socket, the red indicator of source power of the charger is
lit up, while the charging status green indicator is lit, that means the battery is
in the status of charging; and when the green indicator faded, that means the
battery is charged full. Generally, the charging period takes 10-12 hours.
4.3. Shall the charged battery shows low voltage status during heavy duty job,
probably the battery is damaged or the charger is in trouble.
5. Safety Belt
5.1. Safety belt is a safety device provided for preventing the transmission chain
to break suddenly and that may cause equipment damaging. The device makes
the elevator possess the characteristics of safe and reliable.
F. DAILY MAINTENANCE & PERIODIC INSPECTION
1. Check if right every day for each status indication, including the smoothness
and stability of platform up-climbing and down-descending.
2. Check once a month if any deformation, connection loosening, wearing and
abnormal sound for connecting bolts, wheels, rolling bearings, transmission
chain, structure parts and moving parts.
3. Check once a month the jiggling, wearing, lubricating, and loosening for
chain, sprocket wheel, chain-trolley and connecting bolts inner transmission box,
grease in time, as well.
4. Once each three months check control panel, charger, battery and electric
control wiring if any loosening inner transmission box and the inner box cleaning.
5. Check each month the bending and deforming status of the pole, and if the
flexible and smooth for the safety belt protruding and retrieving.
3 | 01-2811700 • ajproducts.ie