Herunterladen Inhalt Inhalt Diese Seite drucken

Clean Contact Connection; Default Setting; Operating Logic; Additional Setting - Gewiss JOINON WALLBOX I-CON PREMIUM Installations- Und Bedienungsanleitung

Ladestation für elektrofahrzeuge joinon wallbox i-con
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 162
JOINON WALLBOX I-CON PREMIUM electric vehicle recharging unit
13.
76

CLEAN CONTACT CONNECTION

The charging station has a clean contact that can be used by external devices to check the charging station,
intervening in the current charging process.
The operating logic is combined with the position of selector number 4 of the DIPSWITCH on the electronic board.

13.1 DEFAULT SETTING

The default setting for selector n. 4 of the DIPSWITCH is OFF

13.1.1 OPERATING LOGIC

With the selector in this position, the operating logic is
ENABLING CONTACT
Open
Closed

13.2 ADDITIONAL SETTING

It is possible to change the position. The default setting for selector n. 4 of the DIPSWITCH is OFF
13.2.1 OPERATING LOGIC
With the selector in this position, the operating logic is
ENABLING CONTACT
Open
Closed
COLLEGAMENTO
USER CONNECTION
UTENTE
VEHICLE CHARGING MANAGEMENT
Charging enabled without external limitations.
The logics of the ECO or DLM mode are actuated
depending on how the charging station is set
Charging blocked or suspended
Charging is blocked if the signal arrives when the
station is in standby
Charging is suspended if the signal arrives when
the station is charging
VEHICLE CHARGING MANAGEMENT
Charging blocked or suspended
Charging is blocked if the signal arrives when the
station is in standby
Charging is suspended if the signal arrives when
the station is charging
Charging enabled without external limitations.
The logics of the ECO or DLM mode are actuated
depending on how the charging station is set

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis