For Your Safety:
PLEASE READ THIS MANUAL IN ITS ENTIRETY
INSTALLATION OR OPERATION! Attempting to operate this tool without fully
understanding its features and functions may result in unsafe conditions.
Analyzer Warnings
o REFRIGERANT BLEND WARNING: Operate this unit with vehicles or
o SAMPLE HOSE WARNING: Replace the sample hose AS SOON AS
o FLAMMABILITY WARNING: Some vehicles may contain flammable
o SAMPLE INPUT WARNING: DO NOT attempt to introduce liquid or
o BATTERY CHARGING WARNING: When charging the internal battery with
o AIR SENSOR WARNING: The air detection sensor is a chemical fuel cell
o POWER SOURCE WARNING: Connection to power sources greater than
o OPPERATIONAL WARNING: If the equipment is used in a manner not
Manual Part Number:
5-06-7000-80-0
cylinders marked to contain R-1234yf, R-134a or R-12 refrigerant. Cross-
contamination with other refrigerant types causes severe damage to the
A/C system, to service tools, and equipment. Do NOT attempt to adapt the
unit for another refrigerant. Do NOT mix refrigerant types in a system or in
the same container.
LIQUID, OIL OR RED SPOTS (DISCOLORATION) BEGIN TO APPEAR
ON THE INSIDE DIAMETER OF THE SAMPLE HOSE OR WHITE FILTER
ELEMENT. Failure to properly maintain and replace the sample hose will
result in severe damage or inaccurate results.
refrigerants such as hydrocarbons. R-1234yf is considered a flammable
substance. Failure to follow the manual can result in serious injury or
death. Less than 2 grams of refrigerant are vented with each sample. This
analyzer is designed with sealed heat sources and without sparking
components.
samples heavily laden with oil into the Low Side sampling hose
configuration. Damage caused to the instrument due to the use of the
wrong hose configuration on the wrong port will void the warranty!
the supplied power supply, the power supply may become warm. If the
power supply becomes warm, unplug the cord immediately!
charging multiple analyzers, allow the charger to cool between each
battery.
sensor that will eventually expire. The user must return the unit to an
approved vendor in order to replace the air detection sensor whenever the
instrument indicates as such. Failure to replace the air detection sensor will
result in non-functionality of the instrument.
13VDC could cause "out of warranty" damage.
specified by the manufacturer, the protection by the equipment may be
impaired.
BEFORE
Manual File:
012476 Rev. A
ATTEMPTING
When
Page V