3.5

Error Messages

In the unlikely event an Error message is displayed on the screen, follow the on-screen
prompt associated to the Error. Error messages that will appear include:
Error #1: The air or gas readings were unstable.
Solution: Move the unit away from sources of EMF or RFI such as radio transmitters
and arc welders.
Error #2: The air or gas readings were excessively high.
Solution: Move the unit away from sources of EMF or RFI such as radio transmitters
and arc welders.
Error #3: The air calibration resulted in a low output.
Solution: Prevent refrigerant from flowing into the unit through the sample inlet during
air calibration.
Solution: Allow any refrigerant in the atmosphere to dissipate before performing air
calibration.
Solution: Verify that the air intake and the exhaust are not obstructed.
Solution: Verify that the white filter is correctly plugged into the rubber grommets.
Error #4: The unit is beyond the operating temperature range.
Solution: Move the unit to an area where the ambient temperature is within the
specified operating range.
Error #5: The refrigerant sampled has an excessively large amount of air or there was a little or no
sample flow due to a closed valve or plugged sample filter. This is the code to prompt the user to
change the brass filter. This should be considered more as a prompt than an actual error.
Solution: Verify the coupler valve is open.
Solution: Verify the sample filter is not plugged with debris or oil.
Solution: Replace brass sample filter.
Error #6: The air sensor has expired and must be replaced before the analyzer can be used.
Error #7: The gas pressure is out of range
Solution: Verify the SAMPLE EXHAUST port is not obstructed.
If an Error message reappears, contact Neutronics or your local service department.
Neutronics Inc.
456 Creamery Way
Exton, PA 1934, USA
Tel:
+1 610.524.8800
Fax:
+1 610.524.8807
Contact us:
info@refrigerantid.com
Visit us:
www.refrigerantid.com
Manual Part Number:
5-06-7000-80-0
Manual File:
012476 Rev. A
Page 3-22

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis