The refrigerant analyzer is designed to provide visual cues after analysis is complete. When
the refrigerant sampled is found to be 98% pure or greater the analyzer will display a Green
background indicator (Figure 14).
Figure 14
When the sampled refrigerant is found to be between 95% - 98% pure a Yellow background
indicator will appear (Figure 15).
When the sampled refrigerant is found to be less than 95%, presents hydrocarbons or a has
large contamination the screen will illuminate Red and
WHEN HANDLING THIS VEHICLE OR CYLINDER
It is important to note AIR is measured independently of the refrigerant. This means you
could have a percentage of AIR present in a sample or refrigerant that totals or equals 100%
refrigerant. An example of this is present in (Figure 17) below.
If an error message appears at all during or after analysis. Refer to section
and Troubleshooting.
Manual Part Number:
5-06-7000-80-0
CAUTION SHOULD BE TAKEN
(Figure 16).
Figure 16
Figure 17
Manual File:
012476 Rev. A
Figure 15
Maintenance
3
Page 2-19