If the refrigerant analyzed is 98.0% pure or better, the refrigerant is deemed suitable for
standard recovery and reuse. Should the refrigerant be less than 98.0% pure, the refrigerant
is not suitable for standard recovery and should not be reused. In either case, verify the hose
is disconnected from the refrigerant source and press 'Exit' to return to the main screen
(Figure 11).
Figure 11
NOTE:
In R-134a mode, R-12 and R-1234yf are combined into one reading referred to as
"R-12/ R-1234yf."
2.6
Understanding
Test Results
The Legend ID™ is designed to analyze the base gas it is calibrated for. When testing R-
134a vehicle, R-134a should be select as shown on (Figure 12). Conversely when testing a
R-1234yf vehicle, R-1234yf should be selected as shown in (Figure 13). If the wrong base
refrigerant is selected the analyzer will fail the test and produce inaccurate results.
Figure 13
Figure 12