Herunterladen Inhalt Inhalt Diese Seite drucken

New Features And Protection; More O-Rings For More Support - Seamax SUP20MAX Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NEW FEATURES AND PROTECTION

Fully Suppport Auto Model or Manual Mode. When you inflate a product that the auto model cannot fulfill
your requirement. For example the pump cannot switch to 2
may never need the 2
Simply press the "HIGH" button to directly start the pump 2
pump with smaller air valve adaptor against the back pressure, such as a boston air valve. You can also press
the "LOW" button to start the pump with 1st stage only. The turbo fan will be on and keep going. But the
pump won't switch to the 2
auto model.
Those combination will help you to use this punp with a wide rage inflatable products, including kayak,
mattress and many other water toys. A built-in cooling fan will extend the pump continued working time to
30 minutes.
Input voltage real time monitoring system. Pump normal working voltage range is 9V-15V. This pump will stop
working or won't start if the voltage is below 9V or over 15V. If the input voltage is too low, the pump will not
have enough power to inflate your inflatable product's air chamber to a higher pressure fast enough. Such
situation will easily cause the pump's piston overheat damage. If the input voltage is too high, it will cause
motor overheat issue and burn the pump electronic components. ERROR icon and voltage reading will keep
blinking when voltage issue detected. The pump will be back to normal after the detected voltage is within its
safe working range (9 to 15V).
Overheat protection. When the pump's internal temperature reaches 85 Celsius degree (85
pump will stop working immediately. And the pump "Start Up" feature will be locked for temporary Self-Protection.
The LCD screen will show a flashing ERROR – OVERHEAT message. The pump will be automatically unlocked after
its internal temperature drops below
to reset the pump. Disconnect the air hose and turn on the pump in cool air for 3 minutes for fast cooling down before
pumping again.
When the air pressure is over 5 PSI and below the user's set pressure, the pump will start monitoring the
pressure increment. If the pressure increment is less than 0.05 PSI after 20 seconds continuous running, the
Pump Self-Protection will be activated and stop working. User should check all the connection and O Rings
size to make sure all components' air tight and right fit, before start pumping again. If without this self-
protection, the inflator could be permanently damaged in few minutes.
The pump will stop automatically after 20 minutes continuous running regardless the pump's working stage
and condition.
5 |
P a g e
nd
stage pressure too high. You can choice its manual model.
nd
stage. Pressure the same botton again to stop the pump from manual mode or
50
°C (
122
°F). To bypass this waiting period, user can reconnect its power plug
nd
stage, or switch to 2
nd
stage air compressor. It is suitable for using the
nd
stage too early. Or you
°C
or 185
°F), the

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis