Seamax Portable12V SUP-20D Electric Air Pump for Inflatable SUP, Kite and Inflatable Boat

NEW FEATURES AND PROTECTION

Built-in audible indicator and special message display on LCD screen to notice the pump's status: Startup, Stop, Error,
Overheat, High voltage and Low voltage.
Power Connected
Button Pressed
Voltage Error Detected
Over Suggested Continuous Working Time
Air Pressure Increment Error Detected
Overheat Issue Detected
Input voltage real time monitoring system. Pump normal working voltage range is 9V-15V. This pump will stop working or
won't start if the voltage is below 9V or over 15V. If the input voltage is too low, the pump will not have enough power to
inflate your inflatable product's air chamber to a higher pressure fast enough. Such situation will easily cause the pump's
piston overheat damage. If the input voltage is too high, it will cause motor overheat issue and burn the pump electronic
components. ERROR icon and voltage reading will keep blinking when voltage issue detected. The pump will be back to
normal after the detected voltage is within its safe working range (9 to 15V).
Overheat protection. When the pump's internal temperature reaches 85 Celsius degree (85
working immediately. And the pump "Start Up" feature will be locked for temporary Self-Protection. The LCD screen will show a
flashing ERROR – OVERHEAT message. The pump will be automatically unlocked after its internal temperature drops below
50
°C (
122
°F). To bypass this waiting period, user can reconnect its power plug to reset the pump. Disconnect the air hose and
turn on the pump in cool air for 3 minutes for fast cooling down before pumping again.
When the air pressure is over 5 PSI and below the user's set pressure, the pump will start monitoring the pressure
increment. If the pressure increment is less than 0.05 PSI after 20 seconds continuous running, the Pump Self-Protection
will be activated and stop working. User should check all the connection and O Rings size to make sure all components' air
tight and right fit, before start pumping again. If without this self-protection, the inflator could be permanently damaged
in few minutes.
The pump will stop automatically after 20 minutes continuous running regardless the pump's working stage and
condition.
2 Second Start Up Self Test
EVENT
2x Short Beep and Long Beep (2 Hz)
1x Short Beep
Long Beep for 30 Seconds (3 Hz)
1x Short Beep
Long Beep for 30 Seconds
Long Beep for 30 Seconds (0.5 Hz)
Page 5
www.seamaxmarine.com 1877-907-7766
AUDIBLE INDICATION
°C
or 185
°F), the pump will stop
Pump Standby