GAS CONNECTION

The installation of the gas connection, as well as the laying of
the customer's gas line, is only to be carried out by an authori-
zed specialist subject to the relevant national and local regula-
tions.
NOTE
The gas appliance may only be installed in an adequately
ventilated location.
The appliance is adjusted in the factory for the gas speci-
fied in accordance with the order and the installation site.
The type of gas, gas pressure and gas category are
entered on the specification plate. Before connection,
check that the appliance is set up for the existing type of
gas. To do this, compare the details on the specification
plate with the existing gas data.
If this is not the case, the appliance must be converted or
adapted by the service personnel responsible to suit local
conditions. Observe the following points while doing so:
- Has the appliance been tested for the new gas data?
- Conversion in accordance with the Service Manual.
- A new specification plate or a durable marking with the
new gas data must be affixed to the appliance.
4.1
CONNECTION
Pure gas appliances as well as combined electric and gas
appliances require a gas connection.
The gas connection for the appliance is located at the gas tap
behind the control panel (C). Removing the control panel
(siehe Kapitel 2.2). Optionally a flexible metallic tube 1 m long
can be delivered with the appliance. On the end it has a sleeve
with a G¾" I inner thread. The hose is connected to the gas
tap on one side and the customer-supplied gas supply line on
the other. The threads are to be sealed with Loctite 577.
It is recommended that the customer install a dirt trap device in
the gas line.
After connection, all lines carrying gas must be tested for leaks
at operating pressure by painting with non-corrosive foam-for-
ming media, (e.g. soapy water or leak spray).
4.1.1

FREE-STANDING INSTALLATION

The supply line from the point where the gas supply comes out
of the floor to the connection to the range must be installed by
the owner. Gas connection for all types is G3/4".
4.1.2
FITTING AGAINST A WALL
Prior to fitting the range against the wall, the flexible gas hose
is connected to the customer's gas supply line protruding from
the wall. The gas connection is G3/4". The range is then fitted
against the wall. The flexible gas hose is then drawn through
the appliance and fitted to the range connection.
4.2
WASTE GAS CONTROL
No additional chimney is required on the appliance for any
country. The appliance is below the German 14 kW output limit
value, above which a chimney is required. The waste gases
flow out of the gas outlet located on the side of the large coo-
king area up to the waste air hood or the ventilation ceiling and
are extracted there.