8.11 Using the laser & LED - light (Fig. 2/3)
• To switch on: Press the on / off switch for laser &
LED (28) 1x to switch on the LED light. Press 2x to
switch on the laser. A laser line is projected onto the
material you wish to process, providing an exact
guide for the cut. When pressed for the third time,
both the LED light and laser switch on.
• To switch off: Move the ON/OFF switch of the la-
ser & LED (28) four times.
8.12 Adjusting the laser (Fig. 3)
If the laser (8) ceases to indicate the correct cutting line,
you can readjust the laser. To do so, open the screws
(g) and set the laser by moving sideways to that the
laser beam strikes the teeth of the saw blade (6).

9. Transport

• Tighten the set screw (9) in order to lock the rotary
table (17)
• Activate the release lever (3), press the machine
head (4) downwards and secure with the safety pin
(32). The saw is now locked in its bottom position.
• Fix the saw's drag function with the locking screw
for drag guide (20) in rear position.
• Carry the equipment by the fixed saw table (18).
• When reassembling the equipment proceed as de-
scribed under section 7.

10. Maintenance

m Warning! Prior to any adjustment, maintenance or
service work disconnect the mains power plug!
General maintenance measures
Wipe chips and dust off the machine from time to time
using a cloth. In order to extend the service life of the tool,
oil the rotary parts once monthly. Do not oil the motor.
When cleaning the plastic do not use corrosive prod-
ucts.
Brush inspection
Check the carbon brushes after the first 50 operat-
ing hours with a new machine, or when new brushes
have been fitted. After carrying out the first check, re-
peat the check every 10 operating hours.
If the carbon is worn to a length of 6 mm, or if the
spring or contact wire are burned or damaged, it is
necessary to replace both brushes. If the brushes are
found to be usable following removal, it is possible to
reinstall them.
When servicing the carbon brushes, open the two
latches counterclockwise (as shown in Figure 19).
Then remove the carbon brushes.
Replace the carbon brushes in the reverse order.
26
GB

11. Storage

Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.

12. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment
may only be carried out by an electrician.