Herunterladen Inhalt Inhalt Diese Seite drucken

Pin Connection Xs1 - Footswitch/External Startsignal; Declaration Of Conformity - Henkel LOCTITE 97006 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8
Appendix
8.2

Pin Connection XS1 - Footswitch/External Startsignal

Specification of
the internal relay:
- Dry contact,
- max. 30 W,
- max. 24 VDC,
- max. 1 A.
+ 24V
output
8.3

Declaration of Conformity

The Manufacturer
according to the EC regulations
declares that the unit designated in the following is, as a result of its design and construction, in accordance
with the European regulations, harmonized standards and national standards listed below.
Designation of the unit
Unit number
Applicable EC Regulations
Applicable harmonized standards
Authorized person for technical files
Garching, 18
42
Controller XS1
4
1
Start
2
3
Relay is closed if
controller is ready and
reservoir is not empty.
GND
0VDC
th
June 2013
Footswitch
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Henkel AG & Co. KGaA
Standort München
Gutenbergstr. 3
D-85748 Garching bei München
Digital Syringe Dispenser, Type 97006
88633
EC Directive of Machinery 2006/42/EC
EC Directive for Electro-Magnetic Compatibility 2004/108/EG
EC Directive of RoHS 2002/95/EG
EC Directive of WEEE 2002/96/EG
EC Directive of Low Voltage 2006/95/EG
EN ISO 12100-1+A1:2009
EN ISO 12100-2+A1:2009
EN ISO 14121-1:2007
EN 60204-1; VDE 0113-1:2011-01
EN 50082-1 1992; EN 55014 / 4.1993; IEC 801-2, 3, 4
Henkel AG & Co. KGaA
Standort München
Gutenbergstr. 3
D-85748 Garching bei München
Business Director Adhesive Technologies
External Start
1
2
3
4
2
5
S1
6
1
7
8
9
Never connect 24 V DC to pin 9!
(J. von Ameln)
+ 24V
Input
0VDC

Werbung

Kapitel

Inhaltsverzeichnis

Fehlerbehebung

loading