Herunterladen Inhalt Inhalt Diese Seite drucken

Appendix; Accessories And Spare Parts - Henkel LOCTITE 97006 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7
Troubleshooting
Type of malfunction
No start signal.
No reaction from the buttons.
8

Appendix

8.1

Accessories and Spare Parts

Pos.
Description
No.
10 ml Air Line Adapters (2 pcs/box) .............................................................. 97208
30 ml Air Line Adapters (2 pcs/box) .............................................................. 97245
10 ml Clear Syringe Package (30 pcs/box) ................................................... 97207
30 ml Clear Syringe Package (20 pcs/box) ................................................... 97244
Dispense Needle, Polyethylene – Conical (PPC),
especially for viscous products and large dispensing quantities:
Dispense Needle PPC16GA (50 pcs/box), ID Size 1,19 mm, grey ................
Dispense Needle PPC18GA (50 pcs/box), ID Size 0,84 mm, green..............
Dispense Needle PPC20GA (50 pcs/box), ID Size 0,58 mm, pink ................
Dispense Needle PPC22GA (50 pcs/box), ID Size 0,41 mm, blue ................
Dispense Needle, Stainless Steel – Standard (SSS),
especially for low viscosity and UV curing products:
Dispense Needle SSS15GA (50 pcs/box), ID Size 1,35 mm, amber .............
Dispense Needle SSS18GA (50 pcs/box), ID Size 0,84 mm, green ..............
Dispense Needle SSS20GA (50 pcs/box), ID Size 0,58 mm, pink.................
Dispense Needle SSS25GA (50 pcs/box), ID Size 0,25 mm, red..................
Dispense Needle, Polypropylene – Flexible (PPF),
especially for fast curing products:
Dispense Needle PPF15GA (50 pcs/box), ID Size 1,24 mm, amber .............
Dispense Needle PPF18GA (50 pcs/box), ID Size 0,81 mm, green ..............
Dispense Needle PPF20GA (50 pcs/box), ID Size 0,48 mm, pink.................
Dispense Needle PPF25GA (50 pcs/box), ID Size 0,36 mm, red ..................
Dispense, Appryl (PPS),
especially for drop dispensing; not usable for curing products:
Dispense PPS20GA (50 pcs/box), ID Size 0,6 mm, nature ........................... 97290
Pencil Holder ................................................................................................ 98501
Footswitch .................................................................................................... 97201
Filter Regulator ............................................................................................. 97120
Gri_el halter
Possible causes
– Plug on the socket XS1: Start 25 is
loose.
– Footswitch 20 defect.
– Control unit is defect.
– Button defect.
Correction
● Switch the power switch 10 to the
position O (OFF).
● Tighten the screws of the plug.
● Switch the power switch 10 to the
position I (ON).
● Replace the Footswitch 20.
To test (alternative), use button 4
START.
● Henkel Service.
● Henkel Service.
Type No. Order No.
97221
97222
97223
97224
97225
97226
97227
97228
97229
97230
97231
97232
88657
88678
88656
88677
88660
88661
88662
88663
88664
88665
88666
88667
142640
142641
142642
142643
397462
928058
88653
88649
41