5
Dispensing
5.2.2.2
Continuous Mode
This mode of operation is used for wettings of varying lengths or for the application of
beads.
● With the pressure regulator 9 set the
dispensing pressure to 0.50 bar (approx.
7 PSI).
An error message "Press. 0.83 NOK" with
beeping is possible. The value 0.83
[bar/PSI] is only an example for the
indicated dispensing pressure (see
Chapter 7).
● Press button 2 ENTER to store the
dispensing pressure setting as the
comparison value for automatic
pressure monitoring.
The error message with beeping is
eliminated.
● Press button 6 CONT.
The lighting of the LED in button indicates
continuous mode. The indication of the
dispensing time in the digital display is set
to 0.00 s and blinks.
● Press button 4 START (or the
Footswitch 20) until the dispensed
quantity is roughly achieved.
When the dispensed quantity is achieved too slowly:
● Increase the dispensing pressure and store. Check the dispensed quantity again.
Repeat this sequence until the desired dispensed quantity is roughly achieved.
● Switching back to time-controlled mode without storage of the dispensing time by
renewed pressing of button 6 CONT. The LED in button extinguishes. In the digital
display, the dispensing time previously stored for the time-controlled mode reappears.
● Switching back to time-controlled mode with storage of the dispensing time by pressing
button 3 ENTER. The LED in button 6 CONT extinguishes. The indicated dispensing
time is stored and the display stops blinking.
If the desired dispensed quantity is not achieved:
● With a larger (or smaller) dispensing needle 16, repeat the steps of Section 5.2.2.2.
36
START
bar
START
CONT
psi
START
bar
CONT
psi
bar
CONT
psi