Description
1 Digital Display
Display of the dispensing time [s] for a dispensing sequence.
– During dispensing in time controlled mode, the dispensing time remaining is
indicated.
– During dispensing in continuous mode, the elapsed dispensing time is indicated.
Display of the dispensing pressure [bar or psi] set on the pressure regulator 9.
Display of error messages (see Chapter 7).
2 Button + or
Buttons for changing the dispensing time for a dispensing sequence.
When button + or - is pressed, the display of the dispensing time [s] in the digital
display begins to blink. The dispensing time indicated is increased with button +
and decreased with button -.
The dispensing time is adjustable from 0.01 to 99.9 s.
3 Button ENTER
Button for the storage of the new values set for the dispensing time [s] and the
dispensing pressure [bar or PSI].
When the indication of the dispensing time [s] in the digital display blinks, the
indicated dispensing time is stored by pressing button and the display stops
blinking.
For an error message "Press. 0.83 NOK " with beeping, the error message is
acknowledged by pressing button The value 0.83 [bar/psi] is only an example for
the indication of a dispensing pressure (see Chapter 7).
4 Button START
Button for starting a dispensing sequence. The LED lights for the duration of the
dispensing sequence.
The dispensing time in time controlled mode corresponds to the value on the digital
display and is independent of the length of time that button is pressed
(see Section 2.3.1).
In continuous mode, the product is dispensed as long as button START is pressed
(see Section 2.3.2).
5 Button bar/PSI
Button for switching the measuring units for the dispensing pressure in the digital
display.
After each pressing of button the indication of the selected dispensing pressure in
the digital display changes to the other measuring unit [bar or P] with the
corresponding value.
6 Button CONT
Button for switching from time controlled mode to continuous mode.
The lighting of the LED in button indicates continuous mode (see Section 5.2.2.2).
By pressing button CONT the indication of the dispensing time in the digital display
is set to 0.00 s and blinks. During dispensing, the elapsed dispensing time is
indicated in the digital display beginning each time with 0.00 s. The last dispensing
time remains displayed until the next start.
– Switching back to time controlled mode without storage of the dispensing time
by renewed pressing of button CONT. The LED in button extinguishes. In the
digital display, the dispensing time previously stored for the time controlled mode
reappears.
– Switching back to time controlled mode with storage of the dispensing time by
pressing button ENTER. The LED in button extinguishes. The indicated
dispensing time is stored and the display stops blinking.
-