Dispensing
5.2

First Operation

5.2.1

Purging Air from the Syringe

To avoid air bubbles during dispensing, the tip of the syringe must be purged of air.
Caution!
Hold the syringe 15 over a container since product will flow out!
● Switch the power switch 10 to the
position I (ON).
● With the pressure regulator 9, set the
dispensing pressure to 0.50 bar (approx.
7.00 PSI). The dispensing pressure set
can be read from the digital display.
● Press button 6 CONT to switch to
continuous mode (see Section 5.2.2.2).
● Press and hold button 4 START(or the
Footswitch 20) until the product flows
free of bubbles from the dispensing
needle 16.
● Press button 6 CONT to switch off
continuous mode.
If the product drips out of the dispensing needle 16:
● Turn the vacuum regulator 7 counter clockwise until the dripping stops.
Caution!
Do not continue turning after the dripping has stopped.
When air is sucked in, the syringe must again be purged of air and curing of the product
can occur!