Important! The fitting must installed, flushed and
tested after the valid norms!
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the sink.
3. Slip the plastic washer, the slide washer, the metall
washer and collar over the hoses and threaded
base and tighten the collar nut by hand. If there
is not enough space, please use only the slide
washer and the metal washer without the plastic
washer.
4. Tighten screws.
5. Connect the supply pipes to the isolation valves;
cold right - hot left.
6. Connect the hose with hose nut, taper sleeve,
disc and washer.
7. Mount the hose weight - be careful by the max.
drawn out, otherwise the hose could be crack.
The hot and cold supplies must be of equal
pressures.

Operation

The handspout / handspray can be drawn approx.
45 cm out of the arm lining.
The handspray is activated by pressing the button.
After releasing the button, the mixer returns
automatically to the standard function.
If the waterflow drops, clean the filter located between
hose and handspray.
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.: 65° C
Rate of flow aeratorspray:
Rate of flow showerspray:
Anti-pollution function
English
max. 1 MPa
1,6 MPa
max. 80° C
ca. 10 l/min 0,3 MPa
ca. 11 l/min 0,3 MPa
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Attention!
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
Spare parts (see page 3)
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
aerator cpl.
6
fixing set
7
spout
8
pull out handspray
9
non return valve DW15
10 connection hose 900 mm
11 hose 1750 mm
12 fixing set for hose connection
XXX = Colors
000 chrome plated
800 steel
39891XXX
96338000
98603XXX
96461000
92730000
13913000
95049000
96918XXX
96920XXX
97350000
96316000
96921000
96099000
7