Herunterladen Inhalt Inhalt Diese Seite drucken

Scheduled Maintenance Table - Viper AS710R Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für AS710R:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
USER MANUAL
All maintenance procedures must be performed by qualified personnel, or by authorized
Service Center. This Manual describes only the most common maintenance. For
additional maintenance procedures, contact your local Service Center.
Procedure
Battery charging
Clean Squeegee
Clean Brush/Pad
Clean Tank and vacuum grid
with float, cover gasket
check
Squeegee blade check and
replacement
Recovery filter cleaning
Clean solution pipe filter
Screw and nut tightening
check
lubricate rotary parts
Brush/Pad-holder motor
carbon brush check or
replacement
Vacuum system motor
carbon brush check or
replacement
Drive motor check or
replacement
(1) And after the first 8 working hours.
(2) This maintenance procedure must be performed by an authorized Service Center.
SQUEEGEE CLEAN AND BLADE REPLACEMENT
For optimal performance, the squeegee blades must be clean, dry and undamaged. If
damaged, replace it.
1. Unscrew the knob (B2) to remove squeegee.
2. Unscrew the left and right knob to relax the front clamp, replace the front blade.
3. Disengage the retainers (B4) and remove the rear clamp, replace the rear blade.
4. Install the blades in the reverse order to removal.
5. Install the squeegee to screw the knob (B2).

SCHEDULED MAINTENANCE TABLE

After each use
Weekly
13
ENGLISH
Every six mouths
Annually
(1)
(1)
(2)
(2)
(2)

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

As850r