If the display does not show anything 2 minutes after the
start of the charging process, the battery is defective
and must not be further charged or used and must be
disposed of immediately in accordance with applicable
regulations.
1. Plug the mains cable in the mains cable socket.
Illustration B
2. Plug the mains plug into the socket.
3. Push the battery pack into the mounting on the
charger.
Illustration C
The charging process begins automatically.
Indicator light flashes green.
The battery pack display shows the remaining
charging time. The display shows 100% and the in-
dicator lamp lights up green continuously when the
battery pack is fully charged.
4. Remove the battery pack from the charger after
charging.
5. Pull the mains plug out of the socket.
Note
The charged battery pack can remain in the charger un-
til it is used. There is no danger of overcharging.
Avoid unnecessary energy consumption and unplug the
charger when the battery pack is fully charged.

Wall attachment

The device is suitable for wall attachment. Information
on the weight of the device is provided in the "Technical
data" chapter.
CAUTION
Do not mount the device near or on flammable wall cov-
erings such as wallpaper or wooden panels.
1. Check the load capacity of the wall before installa-
tion.
2. Keep the mains plug freely accessible. Hole dis-
tance = 66 mm.

Transport and storage

CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transport
and storage.
Store the device only in dry indoor rooms.

Care and service

The device is maintenance-free.
 Regularly check the battery terminals for soiling.
 Clean dirty battery terminals.
 Check the ventilation slits for soiling, clean if neces-
sary.
 Occasionally recharge battery packs stored for a
longer period.

Troubleshooting guide

Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
Faults during charging
Battery pack not charging, display is on
Defective charger.
1. Replace the charger.
Battery pack not charging, indicator lamp on quick
charger off, display off
8
The quick charger is defective.
1. Replace the quick charger.
Battery pack not charging, display is off
Battery pack is completely discharged or defective.
1. Wait and see if the display shows the remaining
charging time after 2 minutes.
If the display shows the remaining charging time af-
ter the waiting time, the battery pack can be used
normally.
2. If the display does not appear, the battery pack is
defective and may no longer be used. Immediately
disconnect the battery pack from the charger and
dispose of it according to regulations.
Battery pack not charging, display shows the tem-
perature symbol
The battery pack temperature is too low/high.
1. Put the battery pack in a moderate temperature en-
vironment and wait until the battery pack tempera-
ture returns to the normal range, see the "Technical
data" chapter.
The charging process begins automatically.
Battery pack does not charge, display is off - red in-
dicator light on the charger lights up continuously
The battery pack is completely discharged or defective.
1. Wait and see if the display shows the remaining
charging time after a while.
If the display remains off then the battery pack is de-
fective.
2. Replace the battery pack.
The charger is defective.
1. Please contact the service partner.
Battery pack does not charge, display is off or indi-
cates charging state - red indicator light on the
charger is off
The charger is defective.
1. Please contact the service partner.
Battery pack does not charge, display shows tem-
perature symbol - red indicator light on the charger
lights up continuously
The battery pack temperature is too low/high.
1. Put the battery pack in a moderate temperature en-
vironment and wait until the battery pack tempera-
ture returns to the normal range, see the "Technical
data" chapter.
The charging process begins automatically.
Battery pack does not charge, display shows "bat-
tery pack defective" symbol - red indicator light on
the charger lights up continuously
The battery pack is defective.
1. Replace the battery pack.

Technical data

Electrical connection
Battery pack
nominal voltage
Charging power
max.
Battery pack
type
English
Fast
Fast
Charg-
Charg-
er 18/60
er 36/60
V
18
36
A
6
6
Li-ION
Li-ION
Univer-
sal
Charg-
er 18-36/
60
18/36
6
Li-ION

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis