Herunterladen Diese Seite drucken

RADEMACHER RolloTube S-line DuoFern Kurzanleitung Zur Montage- Und Erstinbetriebnahme Seite 2

Vorschau ausblenden Andere Handbücher für RolloTube S-line DuoFern:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

RolloTube S-line DuoFern
Brief instructions for installation and initial commissioning
Risk of fatal electric shock when touching electrical
components.
◆ The electrical connection of the tubular motor and all work
on the electrical systems may only be undertaken by an
authorised qualified electrician.
◆ Carry out all installation and connection work only in an
isolated, de-energised state.
◆ Disconnect all phases of the mains power lead and se-
cure it to prevent any reconnection.
◆ Check that the system is de-energised.
Requirements for the correct execution of the following
function:
Self-learning operation:
◆ Stopper or end rail on the last slat.
◆ The driver adapter must be mounted with a freewheel mech-
anism. Ties and shaft connectors are both possible here.
◆ If the drive adapter is mounted without the freewheel mech-
anism, then rigid shaft connectors are required for installa-
tion of the roller shutter.
Obstacle detection and fly screen door protection:
◆ The driver adapter must be mounted with a freewheel
mechanism.
Shutter length compensation:
◆ The upper end point must be learned automatically.
Briefly press the set button on the drive head
until the tubular motor starts up briefly. You now
have 120 seconds time to activate the log-on
mode of a DuoFern device.
Please read the operating manual for the
DuoFern device.
The RolloTube S-line DuoFern tubular motors are self-learn-
ing motors with a smooth stop at both end positions. This
eliminates the need to set the end points or a teach-in run.
1.
Switch on the mains power supply. The RolloTube S-line
DuoFern is ready for operation immediately.
2.
Move the roller shutter up and down.
t
The end positions for the smooth stop are
automatically learned during the first drive
cycles.
3.
Subsequently check the direction of travel of the roller
shutter, if the RolloTube S-line DuoFern is being operated
using a switch or button. Switch the lines for the rotation
direction if the direction of travel is wrong.
DANGER!
Example connection with a roller shutter switch / button
Set button
Connect the motor cable to the connecting cable
(2.5 m) supplied by means of a connector and
make the connection according to the following
wiring configuration.
Green/yellow (a) = PE
Blue
Grey
Black
Brown
* The black and brown wires (direction of travel 1 and 2) are not
required for radio operation and therefore not connected.
Risk of crushing injuries to the hand when working with
the roller shutter box open.
◆ Never reach into the area of the winding shaft when the
motor is running.
Before you begin, please read this detailed operating manual
of the RolloTube S-line DuoFern through completely and
follow all the safety instructions and installation instructions.
ATTENTION!
The roller shutter may run into
the roller shutter box and be
damaged without stoppers or
end rails.
◆ Always fit two stoppers or an
end-rail to the lowest slat of the
roller shutter.
protective terminal
(b) = N
neutral terminal
(c) = L
continuous phase
(d) = direction of travel 1 *
(e) = direction of travel 2 *
Initial installation
At the initial installation, the roller shutter engineer can carry
out the end point setting with the help of the set button on the
motor or with a commercially available universal setting ca-
ble, see operating manual of the RolloTube S-line DuoFern.
Universal setting cable
2
1
CAUTION!
Set button
Roller shutter
5
switch or button
a
b
3
L
230 V ~
N
50 Hz
PE
Pin assignment:
The universal setting cable is con-
nected with the same colours as the
3
motor connecting cable of the Rollo-
Tube S-line DuoFern, see above.
Button assignment:
Button 1 = direction of travel 1 / 2
Button 2 = set button
Button 3 = continuous phase
VBD 694-3 (01.20)
Stopper
c
d
e

Werbung