  • DEUTSCH, seite 55

Generator test

Connect the appliance to the battery as described
above under "Connection".
Start the engine and switch on all consumers (head-
lights, radio, rear window heating, etc.).
Increase the number of revs to around 2500 rpm for
a short while.
If the "Charging OK" to "Charging at MAXIMUM"
LED lights up, the alternator/voltage regulator is
working properly. In this LED status, the electrical
voltage in 6 volt mode is approximately 6.7 or
7.3 volts and in 12 volt mode approximately 13.2
or 14.5 volts.
If the "OVERLOAD/Faulty regulator" LED lights up,
the alternator/voltage regulator is defective. In this
LED status, the electrical voltage in 6 volt mode
is approximately 7.8 volts and in 12 volt mode
approximately 15.5 volts. In this case, contact your
local garage.

Cleaning

Danger of electric shock!

nect the appliance from the battery before cleaning
it. Under no circumstances may the appliance be
immersed in water or held under running water
during cleaning.
Attention! Property damage!
aggressive or abrasive cleaning agents, as these can
damage the upper surfaces.
Clean the outside of the appliance with a slightly