Faults, Cause and Remedy

Display
Flow detected during Warm-Up
Blow stronger ! / Repeat Test
Blow softer ! / Repeat Test
Blow longer ! / Repeat Test
Suck after Blow / Repeat Test
Suck longer ! / Repeat Test
Check mouthpiece / Repeat Test
Please retry / Repeat Test
Test Failed
Low Temperature / Warm Up Handset
High Temperature / Cool down Handset Temperature of handset too high
Service required in x days
Service lockout
Cause
Breath sample has been blown too early
Breath sample has been blown too soft
Breath sample has been blown too strong Repeat test blowing softer.
Breath sample has been blown too short
Breath sample is not delivered correctly
by blowing and sucking
Breath sample has been sucked too short Repeat test sucking longer.
Mouthpiece is not correctly inserted into
handset
During delivery of the breath sample a
fault has been detected
The measured breath-alcohol concentra-
tion is above the set limit value
Temperature of the handset too low
Service interval will expire in x days
Service interval expired
Remedy
Deliver breath sample when requested by the instru-
ment.
Repeat test blowing stronger.
Repeat test blowing longer.
Repeat test with blowing and immediately afterwards
sucking.
Insert mouthpiece correctly.
Deliver breath sample again when requested by the
instrument.
Repeat test after at least 15 minutes.
If message reappears, the breath alcohol concentra-
tion is above the limit value.
Detach handset and take it at a place with moderate
temperature. Connect measuring instrument again and
make measurement.
Detach handset and take it at a place with moderate
temperature. Connect measuring instrument again and
make measurement.
Call an authorized Dräger Interlock Service Center in
due time.
Call an authorized Dräger Interlock Service Center.
21