IMPORTANT: Before you continue, it is essential that you read the following instructions carefully.
3.
Hold the points marked  using an open-ended spanner and turn the nuts only at the points marked
 using an open-ended spanner (Select the appropriate spanner according to the dimensions of the
connector).
4.
Ensure that the screw connectors do not skew as you tighten them and work quickly.
IMPORTANT: Since the coupling works with tapping rings, it may leak if you undo and reconnect the pipes.
This will also void the warranty.
5.
After finishing the connection, use the tape to wrap the refrigerant pipe and connecting cable toge-
ther.
6.
After finishing connecting the couple of the quick connectors, pass drain hose and refrigerant pipes
through the wall hole.