5. Troubleshooti ng

Ei²
Ei²Expert
GenSalt OE
INVERSION
"FLASH"
HIGH SALT
/
CHECK SALT
"Salt" indicator
on
NO FLOW
"Flow" indicator
on
CHECK PUMP • This message is displayed
/
PROD. ER-
ROR
/
OVERHEAT-
ING
/
All
/
setti ngs
lost
==> If the problem continues contact your retailer
14
Possible causes
The self-cleaning cycle is automati c;
this message is not an error code
but an informati on message.
• Salt overload (> 10 g/L).
• Lack of salt (< 3 g/L) due to water
loss or diluti on (fi lter backwash,
water renewal, rain, leaks, etc.).
• Pool water temperature too low
(< 18 °C, variable).
• Cell scaled up or worn.
• The fi lter pump has stopped or is
defecti ve.
• Presence of air or gas in the cell
(incorrect fi lling with water).
• By-pass valve(s) closed.
• Flow switch and/or cell
disconnected or defecti ve.
alternately with the "NO
FLOW" message if the situati on
conti nues.
• Short-circuit in the cell or cable
disconnected/badly connected.
• Worn electrode.
• Very low salt or no salt.
• Salt not yet suffi ciently diluted.
• Appliance internal temperature
over 70 °C.
• Appliance internal temperature
over +80°C.
• The appliance has stopped saving
the setti ngs (producti on level,
power, ti me, language, ti mers,
etc.)
.
Soluti ons
• Wait for about 10 minutes and chlorine
producti on will resume automati cally at
the previously set level.
• Parti ally drain the pool to reduce the salt
concentrati on.
• Add salt to the pool to keep the level at
4 g/l. If you do not know the salt level or
how to test it, consult your retailer.
• Basic producti on limitati on signal when
the water is too cold. Reduce chlorine
producti on or add salt to compensate.
• Clean or replace the cell.
• Check the pump and its programming
clock, the fi lter, the skimmer(s), and the by-
pass valves. Clean them if necessary.
• Check the wire connecti ons (cell and fl ow
switch).
• Check that the fl ow switch is working
correctly (replace it if necessary).
• Perform the same checks as above.
• Check the cell connecti ons.
• Replace the cell.
• Have the control box (printed circuit board
and transformer) checked by a qualifi ed
technician if necessary.
• Add salt to the pool to keep the level at 4
g/l.
• The appliance reduces its producti on to
50%.
• Producti on stops.
• Producti on restarts automati cally when the
temperature drops.
• Check the accumulator.
• Replace it if necessary (3V accumulator,
type "CR2032"), see "2.5.2 Connecti on
to an electric roller shutt er" to open and
close the box.
• Reprogramme the diff erent setti ngs in
the appliance, see "", "3.2.5 "SUMMER"
and "WINTER" modes and setti ng the
"Timers"", "3.2.6 "Internal setti ngs" menu".