• The cell must always be the last element placed on the pool return pipe (see diagram).
• It is always recommended to install the cell on a by-pass. This assembly is MANDATORY if the fl ow is in
excess of 18 m³/hour to avoid head loss.
• If you installed the cell on a by-pass, it is recommended to fi t a check valve downstream from the cell
instead of a manual valve, to avoid any risk of incorrect confi gurati on which could result in poor circulati on
inside the cell.
• If the instructi ons on the locati on and orientati on of the cell are not complied with, there could be a
dangerous build-up of pressurised gas which could cause damage, personal injury or even death.
3
An "AUS" reducer and a black gasket are supplied in the installati on kit. They are intended for 1 1/2" (= 48
mm) pipes. However, the black gasket can be used instead of the original gasket if the pipe is not standardised
(diameter smaller than DN 50 or DN 63).
2.4 Installing the fl ow switch (Ei² Expert only)
The fl ow switch and its fi xture collar (Ø50 mm) must imperati vely be installed on the piping close to the cell and upstream
from it. Use the threaded adapter and Tefl on tape supplied to install the fl ow switch on its fi xture collar.
• Cell installed on a by-pass: the fl ow switch must be installed on the cell by-pass between the upstream isolati on valve
and the cell itself.
• Cell installed in line: the fl ow switch must be installed just in front of the cell and aft er a possible valve.
• Att ach the fl ow switch using using the clamping nut only (screw by hand!).
Securing
nut
• Failure to comply with these instructi ons could lead to the destructi on of the cell! The manufacturer cannot
be held liable in this case.
• The fl ow switch has a directi on for installati on (arrow indicated on it showing the fl ow directi on for the
water). Make sure that it is correctly placed on its fi xture collar so that it stops the salt water chlorinator
producti on when fi ltering is stopped ("No fl ow" displayed showing the absence of fl ow, see "5.
Troubleshooti ng").

2.5 Electric connecti ons

2.5.1 Connecti ng the control box

The salt water chlorinator can be connected in compliance with the applicable standards in the country of installati on.
Ei² - GenSalt OE: Mandatory connecti on: directly coupled to the pool fi ltrati on system (the appliance is only supplied with
power when a fi ltering cycle is running).
Ei² Expert:
• Preferred connecti on: the appliance is permanently plugged in to the power supply (power supply protected by a 30
mA residual current circuit breaker).
• Possible connecti on: directly coupled to the pool fi ltrati on system (the appliance is only supplied with power when a
fi ltering cycle is running).
==> When all connecti ons (electrical and hydraulic) have been made, reconnect the mains power supply to power on the
appliance.
• Failure to comply with these instructi ons could lead to the destructi on of the cell! The manufacturer cannot
be held liable in this case.
• Whichever connecti on is used, it is mandatory to programme the Ei² Expert operati ng ti mes (called
"Timers") (see "3.2.5 "SUMMER" and "WINTER" modes and setti ng the "Timers"").
EN
7