After use

Disconnection

1.
Disconnect the DP1 supply hose from the Divator SCUBA while it is
pressurized.
2.
Close the DP1 cylinder valve on the DP1 supply cylinder.
3.
Vent the supply hose by using the vent handle (not through the venting
valves on the adapter hoses).
WARNING
Always use hearing protection when discharging high
pressure air.
4.
Protect all couplings with dust covers or park them in their parking
connections.

Cleaning

1.
Clean the hose, belt and carbine hook with a cleaning solution consisting
of 10 % soap and fresh water.
2.
A degreasing agent can be used to clean badly polluted parts. Before
using such agent contact the manufacturer of it to check if it is suitable in
combination with the type of materials used in Divator DP1 Surface
Supply. Follow the instructions received from the manufacturer.
3.
Mechanical parts must be carefully cleaned so that sand or dust are
removed from the moving parts.
NOTICE
Remember to keep the surface supply pressurized when
washing in soap and water.