The Prog/Current connection can be used to connect a CurrentWatch. The CurrentWatch will show the current used by your equipment. If you are
interested in this product, please contact your supplier.
Wire cross section
Use at least the following wire cross section for the bolt connection:
BP40 min 10mm
2
2
BP60 min 15mm
2
BP200 min 50mm
In difficult environments it is advised to use larger cross sections.
Specifications:
Auto detect 12 or 24V Battery voltage
8-20V
->
20-35V
->
10 programmable voltage thresholds
Over voltage shut down
> 16V
(12V mode)
> 32V
(24V mode)
Current in use ~ 4mA
Current in OFF position or under- or over-voltage position
Maximum Load (shut down current)
BP40
:
BP60
:
BP200
:
Peak current
BP40 & BP60
BP200
Shut down at overload after 5 sec. (after 1 minute start up)
Connections
ON/OFF switch
Alarm buzzer or relay
CurrentWatch current sensor
Voltage drop
BP40
:
BP60
:
BP200
:
Voltage tolerance
Current output tolerance +/- 20%
Water proof
The BP will shut down after about 5 seconds when overloaded. After about 60 seconds the BP will start up again.
Programming table
12 Volt mode
Undervoltage
Threshold
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
Position 7
Position 8
Position 9
Position 10
Position 11
Normal Alarm
Position 12
Relay function
Position 1 & 11 Default positions
12V mode
24V mode
~ 40A (45A)
~ 60A (65A)
~ 200A (210A)
:
120A
:
480A
~ 0,0875 @35A
~ 0,125 @ 50A
~ 0,1125 @ 180A
~2%
IP66
Uppervoltage
Threshold
10,5V
10 V
9,5V
11,25 V
11,5V
10,5V
11,5V
11,8 V
12 V
10 V
FUSE
_
+
~ 2mA
+
Sense
_
CurrentWatch
(Optional)
24 Volt mode
12 V
Position 1
11,5V
Position 2
11,5V
Position 3
13,25 V
Position 4
13,8 V
Position 5
12,8 V
Position 6
12,8 V
Position 7
12,8 V
Position 8
13 V
Position 9
13.2 V
Position 10
Position 11
Position 12
_
BatteryWatch
(Optional)
Input+
Output+
Alarm
Buzzer
Undervoltage
Threshold
21 V
20 V
19 V
22,5 V
23 V
21 V
23 V
23,6 V
24 V
20 V
Normal Alarm
Relay function
+
BG40/60
Output+
BG200
ON/OFF
(Closed=OFF)
Uppervoltage
Threshold
24 V
23 V
23 V
26,5 V
27,6 V
25,6 V
25,6 V
25,6 V
26 V
26.4 V
5 - BG.070227