Herunterladen Diese Seite drucken

Victron energy Battery Protect 40 Gebrauchsanweisung Seite 3

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BP60
BP200
Spanningsnauwkeurigheid
Stroom nauwkeurigheid +/-20%
Waterdicht
IP66
Programmeer tabel
12 Volt mode
Onderspanning
Positie 1
Positie 2
Positie 3
Positie 4
Positie 5
Positie 6
Positie 7
Positie 8
Positie 9
Positie 10
Positie 11
Normale Alarmering
Positie 12
Relais functie
Position 1 & 11 Standaard instelling.
Normaal alarm : Alarm uitgang wordt geactiveerd in geval van alarm; deactivatie na 1 minuut
Relaisfunctie: Alarm uitgang wordt geactiveerd in geval van alarm; deactivatie bij het bereiken van de bovenspanning.
Read the owners manual carefully before installing the BP!
Owners manual BP40 / BP60 / BP200
The new Battery Protect BP40/60/200 (hereafter called BP) is an intelligent, waterproof, Battery Protect with accessory connections for a ON/OFF
switch, Alarm buzzer or relay and our CurrentWatch current sensor (not included). The unit has two bolts as connection for the Input+ and the
Output+ to guarantee low losses. Other connections, like the minus and the accessories, are made by a 4-pole 6.3mm faston connector. A blue LED
shows the status (ON/OFF). In program- mode it shows the program position. The BP has an 'Automatic system voltage Detection'; the BP detects
which battery voltage (12 or 24V) is used. This does not need to be programmed manually. There is a choice of 10 on/off threshold voltages, for both
12V and 24V, which can be programmed in a simple way. The BP uses very little current. In the OFF mode or when in under voltage the BP uses just
2mA or less.
Installation
The installation of the BP has to be done by qualified personnel. Working with batteries is not without danger. Use wires of sufficient diameter and
connectors of good quality. All connections have to be done via a fuse of the right value. See for a guiding principle for the wire diameter the separate
chapter. Attention! Live wires should never make contact with the case of the BP or the vehicle. Wrong connection could damage the electronic circuit.
Mount the BP on a cooling (metal) surface, so it can dissipate the generated heat. Mount it as close as possible to the battery (max. 50cm). This is the
only way to exactly guard the voltage of the battery. Wait with connecting the equipment until the BP is fully programmed. Use a 1.5mm
minus connection which is directly connected to the battery. No other equipment should be connected to this wire.
Programming
To start the program mode a connection should be made between the Input+ and the ProgramInput. The LED will start flashing. The number of flashes
represents the program-position (see table) it is in. As soon as the desired program-position is reached the connection, between the Input+ and the
ProgramInput, should be removed. To confirm the programmed position the LED will repeat the number of flashes. If it is not the right position, the
previous steps have to be repeated. A change in position 11 or 12 has to be programmed separately. The programmed positions will be remembered,
even if the battery connection has been removed. After completing the programming the equipment can be connected.
ATTENTION! First remove the battery-connection, connect the equipment to the Output+ and then reconnect the battery.
Default program-position is position 1 and 11. See program table.
Remote ON/OFF
:
ca. 0,125 @ 50A
:
ca. 0,1125 @ 180A
ca.2%
Bovenspanning
10,5V
10 V
9,5V
11,25 V
11,5V
10,5V
11,5V
11,8 V
12 V
10 V
24 Volt mode
12 V
Positie 1
11,5V
Positie 2
11,5V
Positie 3
13,25 V
Positie 4
13,8 V
Positie 5
12,8 V
Positie 6
12,8 V
Positie 7
12,8 V
Positie 8
13 V
Positie 9
13.2 V
Positie 10
Positie 11
Positie 12
Onderspanning
21 V
20 V
19 V
22,5 V
23 V
21 V
23 V
23,6 V
24 V
20 V
Normale Alarmering
Relais functie
Bovenspanning
24 V
23 V
23 V
26,5 V
27,6 V
25,6 V
25,6 V
25,6 V
26 V
26.4 V
2