Consumed Amp-hours
Example:
If a current of 12 A is drawn from a fully charged battery for a period of
3 hours, this readout will show -36.0 Ah.
(-12 x 3 = -36)

State-of-charge

Time-to-go
The time-to-go displayed is the time to reach the discharge floor.
See 4.2.2, setting number 16.
Battery temperature
The value can be displayed in degrees Celsius or degrees Fahrenheit.
See section 4.2.5.
Battery bank top section voltage
Compare with the bottom section voltage to check battery balancing.
For more about battery midpoint monitoring, see section 5.2.
The amount of Ah consumed from the
battery
A fully charged battery will be indicated by a
value of 100.0%. A fully discharged battery
will be indicated by a value of 0.0%.
An estimation of how long the battery can
support the present load until it needs
recharging.
BMV-702 only, when the auxiliary input is
set to TEMP
BMV-702 only, when the auxiliary input set to
MID.