Herunterladen Diese Seite drucken

Setup Wizard; Battery Capacity - Victron energy BMV-700 Anleitung

Battery monitor
Vorschau ausblenden Andere Handbücher für BMV-700:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 113
1 QUICK START GUIDE
This quick start guide assumes that the BMV 702 is being installed for the
first time, or that factory settings have been restored.
The factory settings are suitable for the average lead acid battery:
flooded, GEL or AGM.
The BMV will automatically detect the nominal voltage of the battery
system immediately after completion of the setup wizard (for details and
limitations of automatic nominal voltage detection, see section 3.8).
Therefore the only settings which need to be made are the battery
capacity (BMV 700 and BMV 700H), and the functionality of the auxiliary
input (BMV 702).
Please install the BMV in accordance with the quick installation guide.
After inserting the fuse in the positive supply cable to the main battery,
the BMV will automatically start the setup wizard.
The setup wizard below must be completed before other settings can be
made.
Remarks:
a) In case of Li-ion batteries, several settings may have to be changed.
Please refer to section 6. The setup wizard below must be completed
before other settings can be made.
b) When using a shunt other than the one supplied with the BMV,
please refer to section 3.6. The setup wizard below must be completed
before other settings can be made.

Setup wizard:

1.1 Battery capacity

a) After inserting the fuse the display will show the scrolling text
If this text is not shown, press SETUP and SELECT simultaneously during
3 seconds to restore factory settings or go to section 4 for full setup details
(setting 64, Lock setup, must be OFF to restore factory settings, see
section 4.2.5).
3

Werbung

loading

Diese Anleitung auch für:

Bmv-700hBmv-702Bmv-700hs