Herunterladen Diese Seite drucken

Victron energy BMV-700 Anleitung Seite 6

Battery monitor
Vorschau ausblenden Andere Handbücher für BMV-700:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 113
b) Press any button to stop scrolling and the factory default value
will appear in edit mode: the first digit will blink.
Enter the desired value with the + and – buttons.
c) Press SELECT to set the next digit in the same manner.
Repeat this procedure until the required battery capacity is displayed.
The capacity is automatically stored in non-volatile memory when the last
digit has been set by pressing SELECT. This is indicated with a short beep.
If a correction has to be made, press SELECT again and repeat the
procedure.
d) BMV 700 and 700H: press SETUP or + or – to end the setup wizard and
switch to normal operating mode.
BMV 702: press SETUP or + or – to proceed to auxiliary input setting.
1.2 Auxiliary input (BMV 702 only)
a) The display will show
b) Press SELECT to stop scrolling and the LCD will show:
Use the + or – key to select the required function of the auxiliary input:
for monitoring the starter battery voltage.
for monitoring the mid-point voltage of a battery bank.
MID
MID
MID
MID
for using the optional temperature sensor
Press SELECT to confirm. Confirmation is indicated with a short beep.
c) Press SETUP or + or – to end the setup wizard and switch to normal
operating mode.
The BMV is now ready for use.
When in normal mode the backlight of the BMV switches off after no key
has been pressed for 60 seconds. Press any key to restore backlight.
The cable with integrated temperature sensor has to be purchased
separately (part no: ASS000100000). This temperature sensor is not
interchangeable with other Victron temperature sensors, as used with
Multis/Quattros or battery chargers.
4
scrolling.
Ah

Werbung

loading

Diese Anleitung auch für:

Bmv-700hBmv-702Bmv-700hs