Caution!
Beware of hot sprayings while cleaning the group. (danger of injury).

7.3 Maintenance

Vorsicht!
Make sure that the machine is disconnected from the power supply during maintenance and
when replacing parts.
Replacing the group gasket and the shower screen
1. Switch off the machine, disconnect the power cord and make sure that the machine is cooled down to
room temperature.
2. It is recommended to remove all the removable parts (cup warming tray, water tank lid, water tank, drip
tray), then turn the machine over.
3. Loosen the countersunk screw in the middle of the brew group and the shower plate with an Allen key
(3 mm)
4. The shower screen and the shower holder (brass) can be removed easily.
5. Under the shower holder is a thin ring, the gasket of the shower plate.
6. The group gasket can only be removed by inserting a thin screwdriver between shower holder and group
gasket. Pry out the group gasket (the old group gasket will be damaged / destroyed).
7. Clean the groove completely, before installing the new group gasket.
8. When inserting the group gasket, make sure that the bevelled side is facing upwards so that it is no
longer visible.
9. Press the group gasket gradually into the pre-cleaned groove.
10. Then screw in the shower plate and the shower holder.
11. In order to ensure that the group gasket is inserted properly, carefully clamp a portafilter without filter
into the brew group.
12. The brew group is ready for use again.
Follow the steps as indicated below:
1.
Brew group at the beginning
4.
Remove the thin gasket of the
shower tray
Translation of the original German user manual
2.
Remove the countersunk screw in
the middle of the brewing unit
5.
Now the group gasket can be
removed.
3.
Remove the shower screen and the
shower plate
6.
Remove the group gasket with a
screwdriver