PROBLEM
Short run time

Technical data

Solution Tank
Recovery Tank
Driving system
Cleaning rate
Cleaning path width
Squeegee width
Brush motor
Vacuum motor
40 |
40 |
40 |
English
CAUSE
Low battery charge
Batteries need maintenance
Defective battery or end of battery life
Faulty charger
Brush pressure set too high
- TECHNICAL DATA -
RA705 IBC
90 l
106 l
24 VDC / 450 W
2950 m
/h
2
700 mm
1151 mm
2*0.5 KW 200 rpm
0.64 KW
SOLUTION
Charge batteries
See BATTERIES
Replace batteries
Replace battery charger
Lower brush pressure
Technical data
Brush pressure
Voltage
Gel Battery
Intelligent charger
Run Time Per Charge
Noise Level
Volume (L*W*H)
Weight (with battery)
RA705 IBC
20-54 kg
24 VDC
4x 6 V / 180 Ah
25 A
4.5 h - 5 h
67 dba
1389×560×1095 mm
350 kg

Quicklinks ausblenden: