Herunterladen Inhalt Inhalt Diese Seite drucken

Chapter Vi Common Faults - SATA AE5151 Bedienungsanleitung

4 tverbreitertelektrisch portalhebemaschine
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39

Chapter VI Common Faults

S/N
Common Faults
1
Button fails to work
Contactor fails to operate after
2
energization
The contactor fails to energized
3
and operate
O i l l e a k a g e o c c u r s a t t h e
4
connection of hydraulic system
5
Oil leakage occurs in the cylinder
The bracket arm teeth do not
6
engage well
Severe burrs appear on the
7
balance wire rope
Left and right sliding tables fails
8
to fall to the same safety position
9
Automatic oil return volume drops
No oil is pumped out when the
10
three-phase motor is working
Abnormal sound is heard in the
11
three-phase motor, or the motor
is powerless
The lowering speed is too low
12
when the lift is loaded
13
The lift shakes during operation
AE5151/AE5151-3
Solution
Replace the button
Replace the contactor
Inspect the button and limit switch
Replace the joint or oil pipe
Replace the sealing ring, or replace the cylinder in severe cases
Adjust the position of the bracket arm teeth
Replace the wire rope
Adjust the balance wire rope nut to synchronize the sliding tables.
Replace the oil return valve or lowering flow regulating valve
The motor rotates reversely. Replace two adjacent power phase wires
(commonly known as live wires).
Phase loss occurs in the motor.
Inspect the incoming power line 380VAC with a multimeter.
Inspect if the oil return valve and lowering flow regulating valve are blocked by
foreign matters.
Apply grease to the post slideway; inspect if the output pressure of the
hydraulic station is stable enough; inspect the cylinder piston rod for climbing.