8. Connecting up
All models of Cordivari electric radiator are fitted with a power cable
complete with a pre-mounted Shuko plug. Before connecting up, make
sure that the rated voltage of the appliance (230V) corresponds with the
mains voltage, and also check to ensure that the wall socket is properly
earthed in compliance with current regulations and that it is capable of
delivering the rated current required to operate the chosen model at full
power.
9. Cautions
When operating normally the radiaotr has very hot surface.
It is normal for the bottom pipes not to heat up.
Only warm towel that has been washed in water.
The resistors on electric radiators must never operate without filling fluid,
and for this reason the connections on the radiator itself must never be
opened.
In the event of accidental overheating and/or improper use, the resisitor
circuit may cut out. In this event the resistor can no longer be used, and
must be replaced.
10. Replacing of electrical immersion
Should it be necessary to replace the resistor, this must be
done exclusively by the manufacturer, by a person with suitable
qualifications, so as to avoid any risks.
Indicator of active heating element
Comfort/Night bar (Chrono mode).
Operating mode icons:
- FIl-Pilote
- Comfort
- Night
- Antifreeze
- Timer 2h
- Chrono
Function: Open Window Detection.
*The version with Fil-Pilot is available for specific countries.
11. Thermostat instructions
Plastic cover: The part connecting to
the heating element is kept hidden by
this special layout, so that the thermo-
stat fits perfectly to the towel radiator.
[Prog] Button
[On/Stand-by]
Button
Water protection:
The IP44 protection
level is guaranteed
by a special design
of the connection
parts.
External sensor:
Guarantees a stable room temperature and a prompt reaction in case
of strong temperature variation.
Day of the week
- 16 -
[+] Button
Display: displays all device
related information
[-] Button
Internal buzzer:
For acoustic warnings, com-
pliant with EN 60335-1 directive.
Configured temperature
24h Indicator
IR receiver indicator
(only version TOP)
Clock
Key-lock icon
Cod. 1910000000048 - nv03