FOR INSTALLERS AND PROFESSIONALS
b. Heating
: adjustable temperature range 18~40℃
c. Cooling
: adjustable temperature range 12~30℃
4. Smart/Silence mode selection:
Smart mode as default will be activated when heat pump is on, and screen shows
Press
to enter Silence mode, and screen shows
(Suggestion: select Smart mode for initial heating)
5. Defrosting
a. Auto Defrosting: When heat pump is defrosting,
b. Compulsory Defrosting: When heat pump is heating, press
defrosting, and
will be flashing. After defrosting,
(Note: Compulsory defrosting intervals should be more than 30 minutes and the compressor should run for more than 10
minutes.)
6. Wifi setting
Please kindly check the last page.

2.3.Daily maintenance and winterizing

2.3.1. Daily maintenance

Please don't forget to cut off power supply of the heat pump when daily maintenance
Please clean the evaporator with household detergents or clean water, NEVER use gasoline,
thinners or any similar fuel.
Check bolts, cables and connections regularly.
2.3.2. Winterizing
In winter season when you don't swim, please cut off power supply and drain water out of the heat
pump.
.
will be flashing. After defrosting,
and
together for 5 seconds to start compulsory
will stop flashing.
Important:
Unscrew the water union of inlet pipe
to let the water flow out.
When the water in machine freezes in
winter season, the titanium heat
exchanger may be damaged.
.
will stop flashing.