[Alarm status] Green tick means the function is active. Alarm status will be
displayed on the screen.
[Switch between channels] Click to enter options settings. You can activate
EN
switch between channels and set interval time. There are 32 variants. Every
option may be modified to add channels.
[Round] Lets you set alarm intervals.
[Return after alarm] Green tick means the function is active. When alarm is
over, round will end and return to main menu.
Steps: Use a mouse to change options or enter data manually. Press [Save] to
save data (fig. 33).
4.5.3 Recording mode
Description of function: Set NVR recording plan parameters.
[CAM] Choose a suitable channel number to set it. You can choose this option
for all channel settings.
[Initial recording] Record 1-30 seconds of initial recording. Its length may vary,
depending on the stream.
[Delays] When the recording has already started, the recording will be delayed
for some period of time.
[Audio coding] Green tick means the function is active. While recording, the
sound will be coded.
[Mode shift]
Time recording: Make an ordinary recording in certain time period.
Recording after detection of motion: Make an ordinary recording after detecting
motion, in certain time period.
No recording: Recording will not be made in a specific time