Operating

Operating
Thank you very much for purchasing the Testboy
polarity and continuity tests can be carried out without having to remove individual components from the battery and re-attach
them. Frequency measurements of the ignition pulses can be carried out. It can also be calculated whether the engine speeds
shown are correct.

Safety information

You have chosen an instrument providing a high degree of safety. To ensure safe and correct application, it is necessary to fully
read this operating manual before using the instrument for the first time.
For test and safety purposes, the instrument has a short-circuit protective device which allows the earthing connection to be exam-
ined without any voltage drop test. The short-circuit system has a restorable fuse thus preventing the technician from destroying the
fuses during the test.
The test leads are long enough for the whole system to be tested without the need to have to regularly find an earthing point.
The presence of voltage could result in a spark flying given contact with the earthing. That is why work should never be undertaken
with a 110/220 mains voltage. The instrument is solely designed for a 12-24 volt supply.
On the circuit-breaker being triggered, do not touch the measurement probe or the measurement probe
adapter. The measurement probe and adapter become vey hot when the circuit-breaker is triggered!
When applying current to components, only press the switch before the measurement probe touches
the component. In this case the arc forms between the probe and the component rather than the
switch. This may extend the service life of the switch.
The following safety precautions apply:
Make sure that the test line and instrument are fully serviceable. Check the instrument on a known source of voltage.
|
If the display fails to indicate one or more functions in the process, do not continue to use the instrument. It must be
|
checked by a specialist.
|
Only hold the instrument on the handles below the mechanical mark; avoid contact with the test probes!
The instrument must not be operated in a humid environment!
|
|
Always keep the instrument dry and clean. Only use a moist cloth to clean the housing.
®