Picture 9. Window
gasket replacement
5.2.6 Filter cartridge replacement
ATTENTION!
Failure to wear approved respirators and eye protection when servicing dust-
laden areas of the cabinet and dust collector, and when emptying the dust
collector could result in serious eye irritation and lung disease or death.
Toxicity and health risk vary with type of media and dust generated by blasting.
The respirator must be approved for the type of dust generated.
Identify all material being removed by blasting, and obtain a material safety
data sheet for the blast media.
Close the air supply to the cabinets and bleed all air from the pulse manifold.
Unscrew the wing nuts and remove the dust collector door. Remove the cartridge
retaining nut, washer, and gasket.
To remove the cartridge, slide it straight down until it clears the holding bar.
Clean all parts that will be reused, especially around the cartridge sealing area. Scrape
off any residual gasket material from the sealing surface.
Install the new cartridge and gasket. Tighten the retaining nut until the cartridge cannot
be moved by hand. Tighten the nut one additional full turn.
Check the collector door gasket for any condition that will prevent the gasket for sealing.
22
CAB-110P/CAB-135P Art. 15205/15206