4.3.8 Timer
Adjust pulse time and cycling on the timer (see drawing X for location).
Use ON scale to adjust the pulse length and OFF scale to adjust the time period
between the pulses.
Begin setting is as follows:
Pulse length (ON scale)
Time between pulses (OFF scale)
5. Maintenance
5.1. Preventive Maintenance
5.1.1 SGV Metering Valve
The SGV metering valve must be regularly inspected for wear. To prolong the life of the
valve, inspect the internal rubber lining regularly for wear and replace when necessary.
5.1.2 Dust container
Empty the dust container regularly. Start by checking the container at least daily or when
adding media, then adjust frequency based on usage, contamination and friability of the media.
18
Picture 5.Pulse time and cycling
adjustment
- 60 ms (by 4.5 bar pulse pressure)
- 5 min
CAB-110P/CAB-135P Art. 15205/15206
CONTRACOR
®