VLZ-SERIES
FD-21 Calibration
1. Switch on the amplifier and turn the volume control
MASTER to zero so that only the 20 kHz test tone is
present at the speaker outputs.
2. Measure the voltage of the 20 kHz test tone at the
connection HIGH IMP and adjust it to 2 V~ with the
trimming control OSC Level
3. Check the voltage of the 20 kHz test tone at the measu-
ring points "+ -"
trimming control Sensitivity
4. After the calibration turn the control MASTER again to
the desired volume.
COM
N.C
COM
LINE IN
HOT
CN602
TEST
RMS 2Vac
CN601
IN
MUTE
+24V
GND
20KHz
Downloaded from
www.Manualslib.com
MODULE FD-21
.
of the module. Adjust 2 V~ with the
.
FD-21 BLOCK DIAGRAM / BLOCKSCHALTBILD DES FD-21
+24V
SENSITIVITY
LEVEL
FD-21
ON
OFF
+24V
OSC OUT
LEVEL
manuals search engine
(optional)
FD-21 Kalibrierung
1. Den Verstärker einschalten und den Lautstärkeregler
MASTER auf Null drehen, damit nur der 20-kHz-Testton
an den Lautsprecherausgängen anliegt.
2. Am Anschluss HIGH IMP die Spannung des 20-kHz-Test-
tons messen und mit dem Trimmregler OSC Level
2 V~ einstellen.
3. An den Messpunkten „+ -"
des 20-kHz-Testtons kontrollieren. Mit dem Trimmregler
Sensitivity
2 V~ einstellen.
4. Nach der Kalibrierung den Regler MASTER wieder auf
die gewünschte Lautstärke drehen.
Operating Condition of FD-21 / Betriebsbedingungen des FD-21
Relay Contact
Line in (COM, HOT)
Condition
(N.O)
20KHz Signal
(N.C)
20KHz No Signal
20KHz
20KHz
Filter
Detector
20KHz
B.A
Generator
des Moduls die Spannung
Speaker Line
AMP Condition
Condition
AMP NORMAL
LINE NORMAL
LINE OPEN or
AMP FAULT
LINE SHORT
auf
13