5. Scope of supply

Casing with accessory package and storage stones
are packaged and delivered separately.
The accessory package includes the following parts:
screws, dowel, washer for tilt protection.
Fixing screws for wall connector blocks.
The wall connector blocks are on the polystyrene
trays.
Please check that everything has been supplied cor-
rectly. Please follow the instructions in the informa-
tion sheet if you would like to report transport dam-
age.
NOTE
Minor damage on the storage stones has no impact
on the operation of the device.

6. Installation location

Please check that the foundation is adequately stable
for the weight of the device. The foundation you store
the device on must be smooth and level.
The device can be installed on any normal flooring. In
the case of vinyl or parquet flooring, or floors with light
carpets, the colour of the floor may be impaired
around the feet due to the effects of pressure or heat.
Sections of wall covering or carpet that come into
contact with the rear of the device must be removed.
A
EN-14
VFE 20 VFE 30
VFE 40
626
776
926
Supporting boards (special accessories) must be used
if:
heat-sensitive floor coverings are present which
can not reliably withstand temperatures over 80
°C.
the feet could sink into the ground, preventing air
exchange underneath the storage heater.
The best place to install the storage heater is under a
window.
If 2 storage heaters are installed next to each other, a
minimum clearance of 20 cm must be observed.
Any objects must be at a distance of at least 30 cm
from the air outlet grid. This is also true for deep-pile
carpet.
VFE 50
VFE 60
VFE 70
1076
1226
1376
A
2007/A
Scope of supply
100
47 mm
www.dimplex.eu