Herunterladen Inhalt Inhalt Diese Seite drucken

Explanations Of Symbols And Safety Instructions; Explanation Of Symbols; Requirements To Boiler Installation Room; Instructions To Boiler Installer - Buroit PyroBurn Alpha Series Technischer Datenblatt Montage- Und Bedienungsanleitung

Pyrolyse kessel
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
1. EXPLANATION OF SYMBOLS AND SAFETY
INSTRUCTIONS

1.1. Explanation of symbols

CAUTION! - Important recommendation or
warning concerning safety conditions during
installation and operation of the heating
boiler
DANGER! - fault or improper use may cause
injury or be hazardous to the life of humans
or animals.
FIRE HAZARD! - fault or improper installation
and operation may cause fire.
INFORMATION - Important information on
the proper operation of the product.

1.2. Requirements to boiler installation room

This manual contains important information for the
safe and correct installation, start-up and trouble-
free service and maintenance of the heating boiler.
The heating boiler can be used for heating rooms
only in the manner described in this manual.
Take note of the boiler type information indicated on
the factory sticker and the technical data provided in
chapter 11.3 in order to ensure proper operation of
the product.

1.2.1. Instructions to boiler installer

During installation and operation, the country-
specific requirements and regulations must be
observed:
• local building regulations on the installation,
air supply and exhaust gas extraction as well as
chimney connection.
• regulations and norms concerning the fitting of the
heating installation with safety devices.
i
Use only original BURNiT parts
DANGER of intoxication, suffocation.
Inadequate inflow of fresh air in the boiler
room may result in dangerous leak of
exhaust gases during boiler operation.
- Make sure the air inlets and exhaust gas
outlets are not clogged or closed.
- If faults are not remedied immediately, the
boiler must not be operated, and the user
must be provided with written instructions
on the fault and the hazard it entails.
It is mandatory to assure a backup power
*
generator of corresponding rated power!
(see 11.3)
Customer must undergo boiler operation/
*
maintenance
installer/service shop.
training
by
authorized
DANGER of fire when burning flammable
materials or liquids.
- Flammable materials/liquids must not be
!
left in immediate proximity of the heating
boiler.
- Indicate to the installation user the allowed
minimum clearances from surrounding
objects.
1.2.2.

Instructions to installation user

DANGER of intoxication or explosion
Toxic gases may be discharged when
burning waste, plastics, liquids.
$
- Use only the fuels indicated in this manual.
- In case of danger of explosion, ignition or
discharge of exhaust gases in the room,
stop the heating boiler from operation.
CAUTION! Danger of injury / damage of
installation due to incompetent operation.
- The heating boiler must be serviced only
by persons familiar with the operation
*
manual.
- As a user, you are only allowed to start the
boiler up, adjust the temperature of the
boiler, shut the boiler down and clean it.
- Unattended children must not be allowed
to access a room housing a running boiler.
Customer must undergo boiler operation/
*
maintenance
installer/service shop.
It is mandatory to assure a backup power
*
generator of corresponding rated power!
(see 11.3)
Safety rules for user operation:
- Operate the heating boiler at a maximum
temperature of 85°C, and to that end you must
regularly inspect the boiler room.
- Do not use flammable liquids to ignite the fire or
increase boiler's output .
- Collect the ash in a fire-proof container with a lid.
- Clean the heating boiler surface using non-
flammable agents only.
- Do not place flammable objects onto the heating
boiler or in its proximity. (see diagram 1 for the
minimum clearances)
- Do not store flammable materials in the boiler room.
1.2.3. Minimum clearances for installation and
combustibility of building materials
The applicable minimum clearances in your country
may differ from the ones specified bellow. Please,
consult your installer.
The minimum distance from the heating boiler or
exhaust gas pipe to objects or walls must be at least
200 mm.
3
training
by
authorized
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis